Genoray Analogue Mammography MX-600 – Medical Grade Professional (Healthcare)
Professional general medical supplies for medical applications. Clinical grade quality, reliable performance. Healthcare facilities.
MX-600 is designed compactly for easy install and operation.
Features:
Auto Standard Positioning system (ASP)
With Auto Standard exposure Positioning systems designed to maximize the convenience of radiography, you can easily adjust positioning by using standard exposure (RCC, LCC, RMLO, LMLO). ASP function makes operators easy to execute 4 axis exposures by software programming. One-touch button controls 4 standard positions (RCC, LCC, RMLO, LMLO) using C-Arm pre-set adjustment (MedioLaterral, Oblique view and CranioCaudal view). The ISO level can adjust the level of MX-600 standing position when it operates from vertical exposure to oblique and vice versa.
Intelligent Automatic Exposure Control (AEC)
Automatic Exposure Control system enables production of images with reliable intensity for any film, screen, or digital radiography. Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which utilizes Auto kV control. It sets the best diagnosis environment by reducing manual operation and increasing patient throughput.
Compression with comfort in mind
When pressure is required for Mammography, it allows you to apply appropriate amount of pressure (up to maximum of 20kg) and is equipped with MICOM control?s Soft-touch system which minimize the discomfort.
Automatic Conversion (Filter)
Motorized and manual breast compressions are available for MX-600. MX-600 displays compression level and thickness on main body?s panel.
Stable Output
A molybdenum (0.03mm Mo) and Aluminum (0.5mm Al) filter are installed to absorb unnecessary x-ray. Mo filter covers low level kV range (22-35kV) and Al filter covers high kV range (35-39kV). Mo filter is useful for increasing image contrast in large breast with large amounts of glandular tissue. The rhodium filter (0.025mm Rh) can be installed as an option (as replacement of Al filter).
Display of Exposure Condition?
When some degree of pressure is required for radiography, it allows you to apply the appropriate pressure (up to a maximum of 20kg) and is equipped with MICOM control?s Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
?
Technical Specifications:
Generator
Type: High frequency inverter (40 kHz).
Radiographic qualification:
Great focus 22-39kV / 1-600mAs.
Small bulb 22-35kV / 1-100mAs.
Tube
Focal point size: 0.1 / 0.3mm.
Anode heat capacity: 300KHU (molybdenum).
Filtration: Mo.
Radiographic support
Movement up / down: 720-1420mm (motorized).
Rotating movement: ? 180? (Motorized) .
Automatic standard positioning (ASP).
SID: 650 mm.
Bucky device
Cassette size: 18x24cm, Grid: 4: 1, 91 lines / inches.
Automatic exposure control (AEC)
Type: solid state detector.
Mode: 3 modes (Full / Semi / Manual).
Density adjustment: 19 steps.
Collimator:?Automatic.
Accessories
Face protection.
Film marker, hand switch, point compression paddle.
18x24cm Bucky device with compression paddle.
Collimating device (18_24 and dotted plate).
Options
Set of Bucky devices of 24_30 cm.
Set of 1.5X or 1.8X magnification devices.
Click Here To Download Catalogue
Description
Medical Grade Genoray Analogue Mammography MX-600
Genoray Analogue Mammography MX-600 designed for medical professionals across Nigerian healthcare facilities. These medical-grade products provide reliable performance for clinical applications.
🔹 Advanced Features & Medical Technology
Manufactured from medical-grade materials with quality construction, featuring durable design, clinical performance standards, regulatory compliance, and professional reliability.
📏 Size Options & Clinical Specifications
Available in multiple sizes and configurations. Professional packaging for healthcare facility requirements.
✅ Medical Certifications & Quality Assurance
NAFDAC registered for medical use in Nigeria with ISO 13485 medical device quality management certification. Manufactured under strict quality control protocols with batch testing and traceability. 5-year shelf life with proper storage conditions.
📋 Clinical Usage & Safety Protocols
Follow standard medical protocols for single-use medical devices. Inspect packaging integrity before use. Store in clean, dry environment at room temperature. Dispose according to medical waste regulations per Nigerian healthcare guidelines.
🏥 Healthcare Facility Applications
Essential across multiple clinical departments including General Practice, Emergency Care, and Specialized Medical Units. Supports doctors, nurses, and medical technicians throughout Nigeria’s healthcare system from primary care to tertiary hospitals.
🛠️ Professional Support Services Nigeria
Comprehensive support includes clinical training programs, 24/7 technical support hotline, inventory management solutions, NAFDAC regulatory compliance support, and bulk pricing for volume purchases.
🚚 Medical Equipment Delivery
Same-day delivery available in Lagos and Abuja, 2-3 days nationwide Nigeria. Temperature-controlled shipping for sensitive medical products with tracking and delivery confirmation.
With Auto Standard exposure Positioning systems designed to maximize the convenience of radiography, you can easily adjust positioning by using standard exposure (RCC, LCC, RMLO, LMLO). ASP function makes operators easy to execute 4 axis exposures by software programming. One-touch button controls 4 standard positions (RCC, LCC, RMLO, LMLO) using C-Arm pre-set adjustment (MedioLaterral, Oblique view and CranioCaudal view). The ISO level can adjust the level of MX-600 standing position when it operates from vertical exposure to oblique and vice versa.
Automatic Exposure Control system enables production of images with reliable intensity for any film, screen, or digital radiography. Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which utilizes Auto kV control. It sets the best diagnosis environment by reducing manual operation and increasing patient throughput.
When pressure is required for Mammography, it allows you to apply appropriate amount of pressure (up to maximum of 20kg) and is equipped with MICOM control?s Soft-touch system which minimize the discomfort.
Motorized and manual breast compressions are available for MX-600. MX-600 displays compression level and thickness on main body?s panel.
A molybdenum (0.03mm Mo) and Aluminum (0.5mm Al) filter are installed to absorb unnecessary x-ray. Mo filter covers low level kV range (22-35kV) and Al filter covers high kV range (35-39kV). Mo filter is useful for increasing image contrast in large breast with large amounts of glandular tissue. The rhodium filter (0.025mm Rh) can be installed as an option (as replacement of Al filter).
When some degree of pressure is required for radiography, it allows you to apply the appropriate pressure (up to a maximum of 20kg) and is equipped with MICOM control?s Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.