Technical Specification:
Dimensions 37.2 x 68 x 44.5 cm.
Weight 33 kg
Flow range 5-10 litres per minute
The oxygen concentration is not lower than 95.5% – 87%.
Maximum discharge pressure 62 ± 4.5 kPa
There is a pressure reduction mechanism at 250 kPa ± 25 kPa.
Altitude: Up to 1,828 meters above sea level without reducing the intensity (at an altitude of 1,828-4,000 meters, efficiency will be below 90%).
Loudness ≤60 dB A
Uses 4 amperes (AC 220V-240V), input power is not more than 850 watts.
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail.
A full 8lpm O2 flowrate capability – gives better performance at lower flow rates
20psi pressure output – your anesthesia system was designed to work from pressure
O2 concentrations average 93% +/- 3%
Built-in Low O2 Concentration Alarm
Small footprint of 15″x15″x22″
Remarkably quiet
Save money over time vs. tanks
Eliminate contamination hazards of tanks coming and going in your facility
Works with ALL manufacturer’s brands of anesthesia systems
.
PSA Medical & Industrıal oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liqiud.
OXYGEN PURITY – PSA oxygen generators, continuously 90-95% purity oxygen produces.
OXYGEN FLOW – LINAIR TECHNOLOGIES manufactures oxygen generators with capacities from 1 Nm3/h to 1000 Nm3/h.
OXYGEN OUTLET PRESSURE – Oxygen generators produces 4-6 bar oxygen.
ADVANTAGES OF OXYGEN GENERATORS/Plant
Consistently high purity guaranteed.
Oxygen production according to your needs 24/7.
Purity control of instantaneously produced oxygen.
Instant monitoring of parameters such as purity, pressure, flow rate on the screen.
No need for an extra operator since it works fully automatically.
Oxygen Hood are cylinder types that enclose an infant’s or small child’s head and adult patients head also. Oxygen enters through a gas Inlet port and exhaled gas leaves primarily through the opening for the neck.
The MultiStim ECO nerve stimulator was developed primarily as a Dual Guidance stimulation device, however, it can also be used for stimulation-supported puncture techniques. The easy-to-use, compact device has been optimised by integrating the most frequently used functions and parameters. This makes handling faster and simpler and the device more cost-effective. The needle can be connected to the device with no additional patient cables required.
Features:
Direct Needle Connection: Connects directly to needle without patient lead
Fixation Directly on the Patient: Adhesive electrode underneath the device with a snap-on button connection
Adaptable Patient Cable: Allows for fixation of the ECO away from the patient. Extended cable length
Fixed Defined Settings: Frequency: 1 Hz / stimulation pulsewidth: 0.1 ms
Variation of the Current Strength: Six-level amplitude scale from 0.2 to 2.0 mA. Arrow buttons are used for the plus/minus key
Click Here To Download Catalogue
With its comprehensive functions, the MultiStim SENSOR can be used for both exclusive nerve stimulation and Dual Guidance. Due to the wide range of adjustment options for the stimulation parameters, the device can also be used for patients with polyneuropathies. By using an optional monopolar stimulation handle, percutaneous nerve localisation can be performed to determine the puncture site for the needle in a patient-friendly manner. By simply pressing a button, switching from percutaneous to subcutaneous stimulation via needle is possible.
Features:
Impulse Frequency: Frequency: 1 Hz, 2 Hz
Stimulation Pulsewidth: Bandwidth: 0,05 ms/ 0,10 ms/ 0,20 ms/ 0,30 ms/ 0,50 ms/ 1,00 ms
Monopolar Stimulation Handle: Percutaneous nerve localization (PEG-electrode)
Optional Connection: Clamp adapter for electrode, Connector for stimulation needle