MX-600 is designed compactly for easy install and operation.
Features:
Auto Standard Positioning system (ASP)
With Auto Standard exposure Positioning systems designed to maximize the convenience of radiography, you can easily adjust positioning by using standard exposure (RCC, LCC, RMLO, LMLO). ASP function makes operators easy to execute 4 axis exposures by software programming. One-touch button controls 4 standard positions (RCC, LCC, RMLO, LMLO) using C-Arm pre-set adjustment (MedioLaterral, Oblique view and CranioCaudal view). The ISO level can adjust the level of MX-600 standing position when it operates from vertical exposure to oblique and vice versa.
Intelligent Automatic Exposure Control (AEC)
Automatic Exposure Control system enables production of images with reliable intensity for any film, screen, or digital radiography. Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which utilizes Auto kV control. It sets the best diagnosis environment by reducing manual operation and increasing patient throughput.
Compression with comfort in mind
When pressure is required for Mammography, it allows you to apply appropriate amount of pressure (up to maximum of 20kg) and is equipped with MICOM control’s Soft-touch system which minimize the discomfort.
Automatic Conversion (Filter)
Motorized and manual breast compressions are available for MX-600. MX-600 displays compression level and thickness on main body’s panel.
Stable Output
A molybdenum (0.03mm Mo) and Aluminum (0.5mm Al) filter are installed to absorb unnecessary x-ray. Mo filter covers low level kV range (22-35kV) and Al filter covers high kV range (35-39kV). Mo filter is useful for increasing image contrast in large breast with large amounts of glandular tissue. The rhodium filter (0.025mm Rh) can be installed as an option (as replacement of Al filter).
Display of Exposure ConditionÂ
When some degree of pressure is required for radiography, it allows you to apply the appropriate pressure (up to a maximum of 20kg) and is equipped with MICOM control’s Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Â
Technical Specifications:
Generator
Type: High frequency inverter (40 kHz).
Radiographic qualification:
Great focus 22-39kV / 1-600mAs.
Small bulb 22-35kV / 1-100mAs.
Tube
Focal point size: 0.1 / 0.3mm.
Anode heat capacity: 300KHU (molybdenum).
Filtration: Mo.
Radiographic support
Movement up / down: 720-1420mm (motorized).
Rotating movement: ± 180˚ (Motorized) .
Automatic standard positioning (ASP).
SID: 650 mm.
Bucky device
Cassette size: 18x24cm, Grid: 4: 1, 91 lines / inches.
Automatic exposure control (AEC)
Type: solid state detector.
Mode: 3 modes (Full / Semi / Manual).
Density adjustment: 19 steps.
Collimator:Â Automatic.
Accessories
Face protection.
Film marker, hand switch, point compression paddle.
18x24cm Bucky device with compression paddle.
Collimating device (18×24 and dotted plate).
Options
Set of Bucky devices of 24×30 cm.
Set of 1.5X or 1.8X magnification devices.
Click Here To Download Catalogue