-
The MIR Spirodoc™ Touchscreen Spirometer with Oximeter is a high quality, portable spirometer used for measuring lung function, as well as measuring oxygen saturation. The Touchscreen Spirometer is ideal for lung and asthma specialty offices, as well as hospitals and clinics.The Desktop Spirometer features a bright, easy to read backlit LCD touchscreen display and a flowmeter head which can detach from the touchscreen to facilitate an oximetry test. Features: Touch screen. Non-invasive. Detachable flowmeter head to facilitate oximetry tests. Spot oximetry test. 24 hour Holter test. Patient eDiary. On-screen results and curves preview for immediate data assessment. Home care symptoms diary. 6MWT (6-Minute Walk Test). Triaxial Accelerometer. Capable of sleep desaturation study. Respiratory Rehabilitation Monitoring. Activity Monitoring. Long life, rechargeable battery. Traffic light health indicator for immediate test interpretation. Wireless real time test on PC via Bluetooth. May be used for both home and office use. MIR Spirodoc Specifications: Unit: Display: LCD backlit touch screen. Resolution: 128 x 64 pixels. Power Supply: Lithium Ion 3.7 V 1100 mA rechargeable battery. Data Transmission: USB 2.0 on-the-go and Bluetooth 2.1. Accelerometer: Triaxial ± 2 g. 400 Hz sampling. Dimensions: 101 mm x 48 mm x 16 mm. Weight: 0.22 lb (99 g). Removable Turbine Head Dimensions: 46 mm x 47 mm x 24 mm. Removable Turbine Head Weight: 17 g. Spirometer: Flow Sensor: Bi-directional digital turbine. Flow Range: ± 16 L/s. Volume Accuracy: ± 3% or 50 mL, whichever is greater. Flow Accuracy: ± 5% or 200 mL/s, whichever is greater. Dynamic Resistance at 12 L/s: < 0.5 cmH2O/L/s. Temperature Sensor: Semiconductor (0 – 45 degrees C). Pulse-Oximeter: SpO2 Range: 0 – 99%. SpO2 Accuracy: ± 2 % (70 – 99% SpO2). Heart Rate Range: 30 – 254 BPM. Heart Rate Accuracy: ± 2 BPM or 2%, whichever is greater.  Click Here To Download Catalogue
MIR Spirodoc – Spirometer with Oximeter
-
Spirometry test: FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Paediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode. Colour screen Touchscreen 7 inches TFT display Database up to 10,000 Spirometry tests or 900 hours of Oximetry recording coupled with powerful and flexible search services. Optional function available: Oximeter with adult or paediatric finger probe. Long life Rechargeable Battery. Available with both DISPOSABLE or REUSABLE turbine flowmeter. PC based mode, using WinspiroPRO® Bluetooth® 2.1 and USB Connectivity Wireless or via cable Real Time test directly on your PC. Winspiro PRO® PC software provides Real Time Flow/Volume and Volume/Time curves with PRE/POST Bronchodilator comparison on your PC. Includes free online updates. Paediatric Incentive for Spirometry with wide choice of pictures and animations. Spirometry test after drug adminitration Bronchodilator Reversibility, Bronchial Challenge with FEV1-response curve with protocols for both Methacholine and Mannitol. Quanjer 2012-GLI Predicted values with LLN and Z-score Patient Trend Charts for easy follow-up Search engine for instant access to database. Wide choice of communication protocols for integration with EMR. Spirometry parameters: FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25–75, FEF75–85, Lung Age, Extrapolated Volume, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/ FEV0.5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated).  Click Here To Download Catalogue
MIR Spirolab Spirometer
-
Water protected switch Energy efficient system V.V.T. nebulizer technology Convenient holder for Nebulizer Kit Handy carry bag Handy shaped Nebulizer Chamber Easy to attach and detach tube connectors
Omron CompA.I.R Pro
-
Features: 1. Capable of capturing both still images and video clips, provides excellent image resolution with full set of features 2. Easy to use measurement calipers for distance and angle measurements 3. Frame-by-frame review of video clips provided for selection of optimal image 4. Patient database and image library is provided with printing and download capabilities  Technical Specifications: A probe Detecting 1.Probe Frequency: 10MHZ  Error±0.5 MHZ 2.Precision: 0.05mm 3.Measurement parameters:  ACD depth, lens, axial length, and its average 4.IOL Calculation: SRK/II, SRK/T, Holladay, SCDK, Hoffer-Q 5.Data Processing: IOL table 6.Operation: Automatic, Manual 7.Information storage: Mass memory Build-in Case data 8.Images reports: External high definition ink-jet printer B probe Detecting 1.B probe mode: Mechanic Sector scans 2.Scan angle: 53° 3.Detect Depth: 50mm 4.Probe frequency: 10 MHZ   Error±0.5 MHZ 5.Resolution: Vertical≤0.5mm, Lateral≤1.0mm 6.Gray Scale: 256 7.Display Mode: B; B+B; B+A 8.Storage: 10 Frames 9.Image Post Processing: Brightness, Contrast, Smooth, Sharp, stretch, Equalize, etc.
Ophthalmic AB Scan Machine
-
The AirSense 10 AutoSet is a premium auto-adjusting therapy device. It features AutoRamp™ with sleep onset detection, expiratory pressure relief (EPR™) and Easy-Breathe technology. The AirSense 10 AutoSet provides advanced event detection, including indications of central sleep apnoea and Cheyne-Stokes respiration. Optional pulse oximetry monitoring is also available. Modes include AutoSet and CPAP. With the wirelessly enabled AirSense 10 AutoSet patient trial devices you can stay more connected than ever before with your patients during their critical early days of adjusting to treatment. Feature New AutoSet Response feature ResMed’s AutoSet algorithm now allows for additional customisation of therapy with the new AutoSet Response feature which offers all the benefits of the enhanced AutoSet algorithm with gentler pressure increases for additional comfort. Central apnoea and Cheyne-Stokes respiration detection The AirSense 10 AutoSet differentiates between obstructive and central apnoeas and can also detect indications of Cheyne-Stokes respiration, so you can be confident that your patients are receiving appropriate therapy. AutoRamp™. This new feature with sleep onset detection starts by delivering a low pressure for greater patient comfort. Then, once the patient falls asleep, it increases the pressure to the prescribed level. Built-in ambient light sensor Adjusts the brightness of the screen based on the light in the room. So if patients need to get up during the night, the screen’s back light won’t disrupt their bed partner. Easy-Breathe motor Is whisper-quiet, offering patients and their bed partners a more peaceful night’s sleep. Expiratory pressure relief (EPR) Maintains the optimal treatment for the patient during inhalation and reduces pressure during exhalation. Consistent humidification Throughout the night with the integrated HumidAir™ humidifier with advanced HumidAir technology helps patients adjust to treatment and use therapy longer. Technical Specification Special User Features: AutoRamp, Intergrated Humidifier, Heated Hose Tube Pressure Range: 4cm-20cm/h2O fixed pressure setting Ramp Time: Auto adjusting ramp feature Starting Ramp Pressure: AutoRamp starting at 4cm/H2O Filters: Standard or Hypo-Allergenic Disposable Device Set-up: Set according to RX or default mode Data Storage Content: SD Card or Wireless Transmission (US Only) to Provider Compliance Meter: On screed display Humidifier: Integrated with Optional Heated Tubing DC Power: 24V —3.75A AC Power: 100-240V, 50-60Hz Actual Weight: 44 oz (2.75lbs) Sound Level: 26.6 dBA with uncertainty of 2 dBA Click Here To Download Catalogue
Resmed AirSense10 CPAP Machine
-
Smith Medical Nasopharyngeal Airway (Portex): Recommended for use in the semi-conscious or unconscious patient with an intact gag reflex. Not easily dislodged during transport and better tolerated than an Oropharyngeal Airway. Designed to be inserted into the nasal passageway to secure an open airway. Features: Robertazzi style Flared end prevents the device from becoming lost inside the patients nose Soft no damage to nasal passage Flexible resists collapse or kinking Latex-free 15mm fitting
Smith Medical Nasopharyngeal Airway (Portex)
-
HotSpirometer cardboard paper mouth piece are suitable for use with the  spirometer. Significantly reduces the risk of cross-infection between patients. Essential Spirometry Consumables. The mouthpiece used in spirometric testing may vary from instrument to instrument. It is essential that the patient puts it between the teeth with the lips around it, so that the air can pass freely and the mouthpiece is sealed firmly by the lips. Dentures are best left in place because they provide essential support to cheeks and lips; however, if they fit poorly and obstruct airflow during the maneuvers it is better to remove them from the mouth.
Spirometer Paper