-
Tonometer is used to measure the intraocular pressure (IOP), the fluid pressure inside the eye. Applanation Tonometers are made and applied under the Imbert-Fick law, and the probe of the tonometer makes contact with the cornea. Tonometer is an applanation tonometry machine for intraocular pressure measurement. It has wide measurement range 0 – 10.64 KPa (0-80mmHg). This tonometer can be mounted on top illumination type slit lamps. Features: Measuring range: 0 – 10.64 KPa (0-80 mmHg) Halo Displacement: 1.53 × 2 = 3.06mm Prism head diameter: 7mm Prism head range of activities: 3mm Specifications: Measuring range 0 – 10.64 KPa (0-80mmHg) Halo Displacement 1.53 × 2 = 3.06mm Prism head diameter 7mm Prism head range of activities 3mm
Applanation Tonometer
-
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer: When used with slit lamp, it can be used to examine the eyes and measure ocular pressure. Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg). Directly get the ocular pressure and do not need to look up the conversion table. The measured ocular pressure is not affected by hardness of eye. The affected?ocular volume is just 0.56 cubic millimeter. Adjustable measuring pressure ensures the long-term stability and reliability. Technical Specifications Applanation Tonometer: Measuring Range: 0~1064 Kpa Light Ring Displacement: 1.53×2=3.06mm Diameter of Prism Head: 7mm Moving Range of Prism Head: 3mm
Applanation Tonometer
-
Features: 7.0-inch color LCD touch panel. Hartman sensor with 108 multiple measure points. Green measurement light beam. Dyeing lens, sunglasses measured easily. Technical Specifications: Sphere lenses: 0~±25D Cylinder lenses: 0~±10D Cylinder Axis Angle: 0°~180° Add.:0~10D Power supply: 100~240V, 50/60HZ, 30W Weight: 5kg
Auto Lensmeter TL-6500B
-
Features: Using the ARM processor and the latest domestic image processing, the system is fast and the image is clear. Japan’s mature optical path system, humanized automatic mist measurement process, to reduce the error caused by adjustment, more precise measurements. Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency. Color LCD display, 5.7 inches man-machine interface is more comfortable. PD automatic measurement function, automatically PD value. One key lock function, quickly locking mobile platforms. Innovative designs, according to the structure of human body engineering, to bring customers good aesthetic feeling and comfortable. Data transmission with CV7200, improved efficiency of online 5x magnification options, respond to different viewing needs. Technical Specifications: Measurement Range Vertex distance…………………………………0.0,12.0,13.75,15mm Sphere…………………………………-20D~+20D(0.12/0.25D step) Cylinder…………………………………….0~±10D(0.12/0.25D step) Axis………………………………………………………1~180°(1° step) PD distance……………………………………………………30~85mm PD………………………………………………………………..10~86mm Minimum pupil diameter……………………………………….Ø2.0mm Target…………………………………………automatic fogging target Hardware specifications Monitor…………………………………………………….5.7″ color LCD Printer………………………………………………Fast thermal printer Power saving function………………..OFF, 5/15 mins (selectable) Power supply…………………………..AC110~220V, 60/50Hz, 50W Dimension/weight…………………………288x500x480mm(14kgs)
Auto Refractometer
-
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature: * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification: Inspection range 90° Inspection distance 30cm Background light brightness White 31.5abs Visual target brightness 1abs — 10000abs Visual target size Goldmann III Visual target interval time 200ms Visual target interval time Stardard or adjustment according to patient reflection Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection Pupil size test Automatic Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve Enviroment light detection Automatic Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis Operation system Win7 above Click Here To Download Catalogue
Automatic Computer Goldmann (Visual Field Analyzer)
-
Ophthalmoscope Features: LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously. Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite. Super lightweight design, reduce fatigue,operation is very convenient. The portable power supply is suitable for surgery, ward round and consultation. This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation. Technical Specifications: Pupilary Adjustment 52mm~74mm adjustable Intensity of Illumination continuous adjustment with the maximum intensity no less than 500Lx Headband 520~640mm in circumference, 85~125mm in depth Light Spots Big spot, middle spot and small spot Filters Red-free, white and cobalt blue Light Source LED light Source of Power Li+ battery, DC 7.4V AC 100~240V, 50/60Hz Input Power Battery charger: 15 VA AC charger: 50VA Dimension of Main Part 142mm × 48mm × 128mm(long×breadth×high) Weight of Main Part 230g
Binocular Indirect Ophthalmoscope
-
Corneal Topography Machine is a diagnostic tool that provides 3-D images of the cornea. The cornea is the outer layer of the eye, responsible for about 70 percent of the eye’s focusing power. Features of Corneal Topography Machine: 1.By PLACIDO cone, 31 rings, a total of 7936 points. 2.Through calculation and analysis, used in the clinical diagnosis of corneal astigmatism, quantitative analysis of corneal shape, display the corneal curvature by data or different colors, can display axial curvature map, tangential curvature map, height map, simulated corneal lens map and corneal 3D map. 3.Can be used in preoperative examination and postoperative effect evaluation of corneal refractive surgery, can guide wearing contact data lens, to improve the accuracy of adaptive contact lens. Technical Specifications of Corneal Topography Machine: Model Measuring method Placido cone Coverage 10.91mm(Diameter) Curvature Radius 5.5mm-10.0mm Diopter Range 33.75D-61.36D Precision ±0.02mm PlacidoRings 31 rings Measurement Points 7936 points Display axial curvature map, tangential curvature map, elevation map, imitated keratoscope map and 3D cornea map Image Output High-quality color inkjet printer Adjust range left/right 86mm ; forward/backward 40mm ; up/down 30mm ; chinrest 5omm Cornea contact lenses fitting function With Keratoconus detecting function With
Corneal Topography Machine
-
Electric E.N.T Examination table is suitable for examination, diagnosing, surgical operation and ophthalmology under the microscope. It designs super-low position stable structure. The table has ophthalmology special accessories. Specifications: Dimensions length: 2030mm width:600mm Height Adjustment(Electric) 580-780mm Head Board Adjustment (Electric) 0-120mm Table Top Lateral Movement (Electric) 0-500mm Standard Accessories: Anesthetic screen frame 1pc Arm supports for doctor 2PCS Arm supports for patient 2PCS Manual controller 1PC Material Stainless Steel base device,plastic-spray cover.the matress is made of sponge with high quality leather cover.
Electric E.N.T Examination (Ophthalmology Special Use)
-
Lens Polishing Machine is a high speed lens grinding and polishing machine comprising a lap tool holder and a gimbal mounted polishing element disposed at its lower extreme in a spherical bearing permitting a lens blank holder to follow the contour of the lens during the polishing process. Features: Exquisite exterior shape, advanced mechanical features. Two pieces of IC plate fitted, automatic timing(0-5 minutes). Powerful motor little noise Specification: Power source: 110V 60HZ, 220V 50HZ Power consumption: 140W Timer: 0~5 minutes Size of buffing wheel: O.D. 115mm(max), Thickness 10mm Unit demension: 214*270*240mm Net weight: 6.7kgs
Lens Polishing Machine
-
Universal or square plastic Loose Prism are useful for a number of orthoptic and ophthalmic test procedures. Available in various set sizes and as single plastic prisms.
Loose Prism
-
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications: Eyepiece focusing range: ±5D The top point diopter measuring range: 0—±20D The minimum measuring square value: 0.125D The shuttle lens measuring range: 5A The shuttle lens square value: 1A The cylinder lens axial range: 0—180° The cylinder lens axial square value: 5° The maximum diameter of the measured lenses l00m/m Power supply: AC 110V-6V DC 3V Note: This item is AC 110V; The battery is not included!
Manual lensmeter
-
Features: The near vision tester enables a complete refractive and binocular vision investigation to be carried out with the head and eyes in their normal posture at any working distance. The refractive tests include: 1.Measurement of visual acuity using Snallen letter and illiterate E-chart,and Times Roman reading types. 2.Accurate determination of presbyopic additions and other near corrections. 3.Near vision astigmatism tests. 4.Amplitude of accommodation including monocular measurements under binocular conditions. The Binocular balance tests include: 1.Fixation disparity test for uncompensated heterophoria motor eye dominance.Accommodation-convergence relationship. 2.Quantitative evaluation of foveal suppression in heterophoria patients. 3.Near point of convergence. 4.Targets for subjective cover tests for heterophoria and harmonious ARC. 5.A centimeter ruler for measuring working and testing distance is included. 6.The chart can be illuminated individually by means of an infra red remote controller Specifications: Test Distance 36cm Distant Control 60cm Size 220(H)×210(W)×42(D)mm Weight 780g Power Supply LR6 AA/1.5V×3
Near Vision Tester
-
Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes. Product features of Non-Contact Tonometer: NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness. Performance Features of Non-Contact Tonometer: 1. Auto 3-D positioning of x-y-z results in precise and reliable measurement. 2. Full-auto measurement for both right and left eye data without manual switch. 3. Easy to operate the tonometer with colour touch monitor. 4. Stable data of IOP through soft air measurement . 5. To compensate corneal thickness measurement of IOP. Technical Specifications of Non-Contact Tonometer: Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg) Measuring system dual sensor system of light and pressure Working distance ≥11mm R/L automatic detection and display Measuring result 10 times per eye; 3 times result printing per eye Recording build-in printer Measuring mode auto/manual Focus when luminous spot is in the focus frame, 2 modes can be chosen. auto mode: auto intraocular pressure measurement manual mode: when it’s good focus, the frame will turn yellow into green, and click to start the measurement Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ” Safety limit button install measurement for minimum distance between head and patient Safety functions the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head. Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical) Jaw layer vertical movement 0~65mm with under jaw layer Display mode 10.1-inch HDMI color LED touch monitor Output port USB2.0 Working platform electric elevating platform Weight 19.7kg size 380 mm (L) x 460mm (W) x 505mm (H) Power supply 220V/50HZ
Non-Contact Tonometer
-
Features: Large color liquid-crystal screen. Touch screen input, easy operation. Curve freezing: Manual/Auto mode, controlled by pedal. Built-in speed thermal printer. Can display ultrasound waveform when measuring. Each group is the average of 20 measurements. Switch between IOP measured value and actual value. Can input name, ID and operator’s name. Technical Specifications: P scan probe 20MHZ, angle of 45 degrees makes easier operation Resolution 5um Measuring range 150um~1500um Display SINGLE mode and MAP mode
Ophthalmic Ultrasound Pachymeter
-
Ophthalmic Unit provides a comprehensive eye consultation which includes dilation, tonometry for glaucoma, along with retina, macula and cataract testing and treatment Features of Ophthalmic Unit: 1.Fashion design 2.Table with rotate and motorized up/down function Specifications of Ophthalmic Unit: Table Dimensions 1040(W)* 1030(D)*1830(H)mm Table size 1000(W)*480(D)mm Lift range for phoropter arm 420mm Power supply AC 220V/55Hz,1 10V/60Hz, 120W Net weight 150.0Kg Chair Lift range for chair 480~630mm Net weight 45.0Kg
Ophthalmic Unit