Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized.
Features:
Easy to install
Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system.
Easy to use
You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display.
Automatic notification system for regular maintenance
Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure.
Self-Test Features
When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety.
Validation of Sterilization of HPS?100
A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.
Â
Specifications
Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge
Total Cycle Time :
1) Smart Mode – 40min
2) Standard Mode – 48min
3) Special Mode – 56min
Cycle Temperature : 45? ~ 60?
SAL(Sterility Assurance Level) : 10-6(Bacillus)
Material – Aluminum
Volume -100L
Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D)
Weight : 180?
Control : 32bit Micro Processor
Cycle Information : 2.7″(OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz
Power Consumption : Max 3.4kw
Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm
Placement : Bult-in wheels provide mobility
Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode/Detail Mode)Â Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)