The MTP carousel tissue processor guarantees gentle and highly reliable specimen processing in conjunction with state of the art control features. The specimen throughput can be doubled to 240 cassettes per run with a second transport basket. For faster and substantially improved processing of tissue, the instrument can optionally be equipped with vacuum units for all paraffin beakers or all positions including reagent beakers. An integrated battery ensures the highest process safety even in environments with frequent power failures. Hazardous fumes are efficiently eliminated by a fume extraction system thereby increasing user safety.
Features of Slee MTP Tissue Processor:
Easy loading and full process control by rotating table principle
Integrated UPS system protects your samples
Up to 240 cassettes per run
Intuitive control panel
Delayed start function
System Status Monitor
Password protected software
Technical Specifications of Slee MTP Tissue Processor:
Nominal supply voltage / frequency:
100 – 240 V AC (+/- 10%) / 50 – 60 Hz
Power draw:
250 VA
Protective class:
(1) I
Power fuses:
2x T 6,3 A
Pollution degree :
(1) 2
Overvoltage installation category:
II
Maximum heat emission:
250 J/s
Operating temperature range:
+10 to +35°C
Temperature range during storage:
+5°C to +55°C
Relative humidity:
max. 80% non condensing
Humidity during storage:
< 8% (1) Lt. IEC 1010, EN 61010
Dimensions (W x D x H):
850 mm x 850 mm x 570 mm
Weight (w/o accessories):
80 kg
Reagent beakers:
Standard: 2000 ml, white, polyacetal, (Optional): 2000 ml, DURAN® glass, (Optional): 2000 ml, aluminum
Paraffin beakers:
2000 ml, aluminum, double walled
Transport basket:
Standard: 1x Stainless steel, capacity 120 cassettes, Optional: 2x stainless steel, capacity 120 cassettes each
Programming:
20 programs (freely programmable), password proteced
Incubation time (Exposure):
1 sec bis zu 99 h 59 min 59 sec (freely programmable)
Drip of time:
30 sec up to 59 min 59 sec (freely programmable)
Paraffin beaker temp.:
Temperature range 40 °C to 80 °C (freely programmable)
Instrument operation modes:
Immediate start Fixed start time: delay programmable by to 999 hours Fixed end time: process end time delayed by up to 99 hours Quick start (factory programmed protocols)
Agitation:
Yes (factory setting for intensity)
Power failure failsafe position:
freely programmable for any protocol step
Control elements:
LCD display System Status Monitor
Vacuum function (optional):
Pressure difference 0,5 bar maximum (500 hPa)
Optional accessories for tailor-made configurations:
Anodized aluminum reagent beakers
Organizer tray
Perspex hood
Fume extraction system incl. charcoal filter
Vaccuum function for paraffin beakers
Vacuum function for reagent and paraffin beakers
TWIN Configuration for two sample baskets
Remote Alarm system