Zenrox offers cutting-edge medical equipment and comprehensive support services in Lagos. Explore our products designed for superior healthcare delivery. Contact us today for innovative medical solutions.
Features:
Convenience:
* AED (Automatic Exposure Detection)
* Up to 3 detectors can be connected
* Emergency Study
* Optimized digital retrofit solution for X-ray system
* Led lamp applied
Speed:
* Cycle time: less than 4.5 sec.
* 1Gbps Ethernet
* Steller gram, our console software, is simple, fast, stable and compatible
* Promix: Signers processing tool
* Client viewer (up to 5 places connectable, coming soon)
Standard Accessories:
Stellar M17 1Pc.
DR: 17″x17″ Wired Detector
CSI with Stellar Gram S/W 1Pc.
Specification:
Sensor: Amorphous Silicon
Scintillator: CSI (Cesium-Iodide)
Active Pixel Area: 427 x 427mm
Pixel Pitch:139µm
Resolution: 3.6 Ip/mm
Pixel Matrix: 3072 x 3072
A/D Conversion:16 bit
Cycle Time: <4.5 sec
Interface (Wire):1Gbps Ethernet
Dimension: 460mm(W) x 460mm(L) x 15mm(H)
Weight: Detector: 4.0kg Console box: 1.1kg
Operation Environment:50C to 350C, 30% to 85% RH
Power: DC 24Vdc, 1.25A
PC Min. Requirements:
CUP: more than Intel Premium G5400
RAM: more than 8GB
OS: Win 10 pro, 64bit
Ethernet Card: Intel Gigabit
Monitor: more than 17”
Click Here To Download Catalogue
High level disinfectant:
Clear green solution.
Active against Helicobacter pylori.
2% glutaraldehyde solution buffered at pH 6 (sodium citrate).
STERANIOS 2%NG and STERANIOS 2%ECS contain compounds
limiting and controlling glutaraldehyde evaporation.
Wide compatibility with all kind of materials.
Shelf-life: 3 years from the production date.
Can be used in association with any kind of cleaning predisinfectant product.
Unit
Brand
sterile Dressing No 7 [Small]
Each
Premium
Sterile Dressing No 8 [Medium]
Each
Premium
Sterile Dressing No 9 [Large]
Each
Premium
Sterile Dressing No 16 [Eye]
Each
Premium
GEMINI offers cost-savings, safety and a high degree of flexibility enabling a smooth laboratory workflow, thus making it a powerful system for all.
FEATURES
Ease of use in application and maintenance
Designed with sample and reagent ID-barcode reading, in-tip dilution reducing consumable costs
Intuitive and highly flexible open software with complete data reduction and LIS interfaces
Integrated PC and touchscreen eliminates the need for an external workstation
Smart time-management allows processing up to 3 microplates simultaneously
SPECIFIATIONS
Reader
Photometric range: 0 to 3.0 OD
Spectral range: 400 nm to 700 nm (up to 8 filters)
Read time: < 15 sec single, < 30 sec dual
Precision: 1% CV at 1.0 OD
Accuracy: ±0.005 OD or 2.5 % (whichever is greater)
Linearity: 0 to 2.000 OD ±1 %
Pipettor
Min / max. volumes: 10 µl to 300 µl with 300 µl tip, 301 µl to 1000 µl with 1100 µl tip
Precision (single dispense): < 3 % CV at 20 µl, < 3 % CV at 100 µl
Precision (multi dispense): < 10 % CV at 16 x 20 µl, < 3 % CV at 8 x 100 µl
Features: Pipetting pressure monitoring, capacitive liquid level detection, tip detection, mixing, multiple dilution steps, archiving
Capacity
Sample and reagent capacity: Up to 192 samples (Flexible: e.g. 144 samples + 8 reagents + 16 controls)
Incubator
Temperature range: Up to 45 °C
Temperature uniformity: ±1.5 °C (with in-process temperature uniformity monitoring)
Shaking: 20 Hz
Washer
Precision: 10% CV at 300 µl
Residual volume: <2.5 µl in U-bottom (mean), <4 µl in flat bottom (mean)
Wash buffer capacity: 3 wash buffers
Modes: Sweep mode, soak, top and bottom wash, variable pump speed
Dimensions
Width x Depth x Height: 125 cm x 65 cm (without waste bag) x 75 cm with closed cover (49” x 26” x 30”)
Click Here To Download Catalogue
Oil Free Lubrication Pump High vacuum, high low
Power Supply: AC220V±10% 50Hz±2%
Input Power: l20VA
Max Vacuum:>90 kPa
Adjustable Vacuum Range: 20 kPa~Max vacuum
Max Airlow: ~20L/min
Suction Bottle (glass): 2500ml/bottle, 2 bottles in a group
Sound Level: 60dB(A)
Dimension: 360 X 320 X 480 (mm)
Weight: 15.5 kg
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system.
Features:
• Good accuracy owning to superior CMOS sensor & our own Algorism
• 10,000 test results data storage
• Instrument Check by Reference Kit
• Remote Support available (when connected via Internet)
• Built-in Thermal Printer and Barcode Scanner
• Data export to USB(PDF, Excel), Email and LIS
• Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃
• Shelf Life of Test Cassette & Buffer : 24 months
Click Here To Download Catalogue
This test quantitatively measures C-reactive protein (CRP) concentration in whole blood, serum and plasma using the INCLIX™ analyzer. For in vitro diagnostic use only.
C-reactive protein (CRP) is synthesized by the liver and is one of the acute phase proteins. In the acute phase response, increased concentrations of a number of plasma proteins, including CRP, are observed. CRP concentration measurements are useful in the detection and evaluation of inflammatory disorders, tissue injury, and infections.
Low level of CRP can be the indicator of cardiovascular disease in apparently healthy people. However, increases in CRP are nonspecific and should be interpreted in the context of a complete clinical evaluation. Apparently healthy individuals with an elevated hsCRP value should have the test repeatedly to rule out a recent response to undetected infection or tissue injury.
This test is a rapid test based on immunochromatography technique “lateral flow” using highly specific monoclonal antibodies. The detection antibody-gold conjugate and CRP leads to the generation of a reddish coloured band on the strip. The intensity of the band depends on the quantity of CRP molecules and is analyzed by INCLIX™ analyzer for quantitative readout.
INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.
Hemoglobin A1c (glycated hemoglobin; HbA1c; A1c) test is the immunochromatography assay and intends for the quantitative determination of stable HbA1c in human blood. In this test system, HbA1c level is expressed in a percent as a good indicator to manage long-term glucose control in diabetes.
The HbA1c Test is the immunochromatography method to determine the percentage of glycated HbA1c in human blood. The detector antibody conjugated with colloidal gold can bind to HbA1c in human blood at conjugate pad where it dried. The detector antibody and HbA1c complex flows through membrane to where capture antibody for total hemoglobin immobilized at membrane of the strip. The signal intensity is measured with the INCLIX™ analyzer and the signal reflectance is calculated and shown as a percentage of concentration with established standard with known the percentage of HbA1c in blood samples.
INCLIX™ PCT Test quantitatively measures Procalcitonin (PCT) concentration in serum and plasma using the INCLIX™ analyzer. For in vitro diagnose use only.
Procalcitonin (PCT) is reliable and specific biomarker to diagnose bacterial infection and sepsis. Because bacterial infection progresses rapidly to severe systemic infection, early diagnosis is important for appropriate clinical treatment. It has been shown that PCT can contribute to optimization of antibiotic therapy and monitor treatment duration.
INCLIX™ PCT Test is a rapid test based on immunochromatography technique “lateral flow”V using highly specific monoclonal antibodies. The detection antibody-gold conjugate and PCT leads to the generation of a reddish colored band on the strip. The intensity of the band depends on quantity of PCT molecules and is analyzed by INCLIX™ analyzer for quantitative readout.
INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout
SGTi-flex COVID-19 IgM/IgG is a gold nanoparticle-based immunochromatographic test kit for qualitative determination of COVID-19’s IgM and IgG antibodies in human whole blood (finger prick or venous), serum or plasma. The kits are accurate and easy to use and results can be observed with the naked eye within 10 minutes.
The test detects the presence of antibodies, which are specific proteins made in response to infections. Antibodies can be found in the blood of those who are tested after infection. The antibodies detected by this test indicate that a person had an immune response to COVID-19, whether symptoms developed from infection or the infection was asymptomatic. Antibody test results are important in detecting infections with few or no symptoms.
As there is no medicine or vaccine, the best way to combat this infection is isolation. A lot of people don’t have symptoms. Because of that, quick diagnostics are very important. SGTi-flex COVID-19 IgM/IgG enables to help for community to identify infection and isolate people without symptoms but suspected COVID-19.
Item Code:: O1-011
Features:
2- piece construction easy to adjust
Plastic material with perforated vents
Padding on the border enhance comfort
:
Ideal to support and immobilize the injured neck, furthermore, help to relieve the pain and speed up recovery. It was made of plastic materials with perforated vents which can provide good ventilation and mobilization. The padding on the top and bottom edge can enhance comfortable, especially 2-piece construction design can adjust the height for a proper fit.
Size Chart:
Size
Height
Circumference of Neck
S
7.5 cm
25~ 30 cm
M
8 cm
30~ 35 cm
L
8.7 cm
35~ 40 cm
XL
10 cm
40~ 45 cm
XXL
10 cm
45~ 50 cm
Composition::
70% PE
15% PVC
10% Foam
5% Cotton
Item Code:: A1-001
Feature:
Immobilizes the injured neck
High density foam provides good cushioning and stabilization.
Adopts the materials are friendly to the skin.
Speed up the recovery
:
The Soft Cervical Collar support the instability injured neck and relieve the pain. It is made of high density foam padding to immobilize and provides support to the neck. Hook and loop closure can easy to adjust for a perfect fit. The soft surface material contains cotton can friendly to the skin, and absorbs the moisture effectively. Provide a proper cushioning and immobilization for the neck and help to speed up the recovery.
Size Chart:
Size
Height
Circumference of Neck
S
8 cm
25~ 30 cm
M
8 cm
30~ 35 cm
L
8 cm
35~ 40 cm
XL
8 cm
40~ 45 cm
XXL
8 cm
45~ 50 cm
Composition:
Foam 70%
Cotton 25%
Nylon 5%