-
The microscope is a device for viewing objects that are too small to be observed with the naked eye. Microscopes magnifies the object under observation. Medical Microscope Features: High Resolution Images of an affected arean Ergonomic design for diagnosis Minimize vibration with 6 Points Arm System (German Imported Products) Option l CCD Camera (Insight I) & Mounted Arm set l LED Light Source l LCD Monitor & Arm set Technical Specifications of Medical Microscope: Field Stop: 020.5 Turret Magnification: x0.4, x0.6, x1.0, x1.67, x2.5, x10 Eyepiece: 55~75(mm) Varifocal: W.D 175!420 (mm), Excluding Monitor and Monitor Arm Dimension: W620xD2040xH1780 Weight: Approx. 100kg Excluding Monitor and Monitor Arm Camera: Option Light Source: LED Lamp Intensity >30,000 Lux Color Temperature: 5700K Feature: Foldable
M.I One Medical Microscope INSIGHT – U+ (M-2100)
-
High quality and reliability thanks to the experience and competence of Swiss engineering for this powerful and clinically safe Piezo scaler Swiss technology Well-proven Swiss Piezo system Permanent feedback control and real-time power adjustments for maximum safety and comfort Precise settings and power delivery for scaling, periodontal, endodontic and restorative treatments Up to 32,000 linear instrument movements per second Product features Powerful Swiss module with minimal operating noise Extremely compact Swiss design Ultraslim lightweight handpiece Large selector for effortless power control Includes Jade device with fully sterilizable quality handpiece 5 instruments for scaling and periodontal treatments (G1, G2, G4, P1, P3) Diaphragm pump and 1 bottle of 350ml (Jade S2) One step foot pedal and external power supply
Maco JADE Piezo Scaler
-
More power toyou. MAGNETOM® Symphony® and Tim (Total imaging matrix) technology -a perfect combination or patient-friendliness and fast scanning capabilities. 5T, 60-cm MR system incorporating Tim technology Available in an 18- or 32-channelcongregation Expands upon the Symphony applications, adding additional inline processing such as Inline Diffusion or automated ADC mapping Nine Tim application suitesstandard, including cardiac,pediatric, and breast Fully integrated coildesign Lightweight (patient-friendly), scalable coils part of the standard congregation
MAGNETOM®
-
The easyScreen unites ABR, TEOAE and DPOAE screening capabilities in one device to meet your need for a cost efficient 2-step ABR/OAE Hearing Screener. easyScreen will lighten your daily workload in many ways: the device fits right into your pocket and helps you save time with its binaural automated ABR screening to test both ears at the same time. The integrated CE-Chirp® stimulus generates accurate pass or refer results within seconds. The device is easy to operate and allows even first-time users to achieve the most accurate results thanks to its on-screen guidance. Features: Fast and accurate ABR + OAE Hearing Screening Powerful automated ABR Screening method with CE-Chirp® stimulus Intuitive user interface and large color touchscreen Pocke tsized and lightweight HearSIM™ patient database and device manager Click Here To Download Catalogue
Maico EasyScreen ABR + OAE Combined in One Hearing Screen Device
-
Fast, portable, easy — our handheld easyTymp performs accurate tympanometry and ipsilateral reflex tests within seconds. easyTymp is not only fast it also eases the process of screening for all professionals: the device automatically increases the intensity of the four frequencies of the ipsilateral reflex test until it detects a reflex or reaches the maximum. With these automatic tests, even first-time users will get the most accurate results. Features: Fast and accurate handheld tympanometer with automatic tests Probe tone 226 Hz, optional high frequency tone 1 kHz Reflex frequencies 500 Hz, 1 kHz, 2 kHz, 4 kHz High resolution, full color display Stores more than 1000 measurements Software included for easy data transfer to a PC Click Here To Download Catalogue
Maico EasyTymp Screening Device
-
ERO•SCAN® provides automated tests with 2 DPOAE and 2 TEOAE screening protocols. Ideal for professionals involved in a hearing screening program or who need a quick assessment of the cochlear system with “Pass” or “Refer” outcomes. An excellent solution for screening newborn, infant, pre-school and nursery children. Features: Fast automatic OAE screening with Pass/Refer results and graphical displays 2 DP and 2 TE protocols for screening devices, 5 DP and 3 TE protocols for diagnostic devices High noise immunity for operation in normal clinical environment Lightweight, small ear probe Sharp colored Organic LED display Wireless communication to PC and optional printer Click Here To Download Catalogue
Maico ERO•SCAN Otoacoustic Emission (OAE) Screener
-
Suitable for in or out of the clinic — the MAICO MA 41 audiometer is designed for the use as a portable audiometer or as a stationary device in your clinic. It is ideal for Audiologists, ENT clinics, mobile facilities or hearing aid suppliers. The audiometer makes air and bone conduction as well as speech and free-field audiometric testing possible. Perform air conduction tests with headphones or optional insert phones as well as through free-field loudspeakers. A B71 transducer is supplied for bone conduction tests. The stimulus options of the MAICO MA 41 include pure tone and warble tone (continuous or pulsed) as test signals as well as narrow band and speech noise as masking signals. Its ergonomic design and easy handling allow for comfortable use the whole day through. Use WAV files from a removable SD-memory card or the input ports for speech from a CD, or conduct live speech audiometry. Features: Tone and speech audiometer with air conduction, bone conduction and optional free-field testing Pure-tone, pulsed and warble as test signals, narrow band, speech noise as masking Individual configuration with extensive settings options Speech tests via WAV files, CD or microphone Optional patient database or NOAH compatible software Click Here To Download Catalogue
Maico MA 41 Audiometer
-
MA 25 offers a full range of testing opportunities. frequencies range from 125 Hz to 8000 Hz and signal intensities run from -10 dBHL to 100 dBHL. Sinus and warble tone (pulsed and continuous) make it complete. FEATURES AT A GLANCE • air conduction with 11 frequencies from 125 to 8000 Hz • customize the frequencies to your own needs • Operated with 3 standard AA batteries or with a medically approved external power supply (optional) • pure, pulse, warble tones • Exceptionally lightweight, only 980 g • Ma 25e extends functionality of Ma 25 SLEEK AND SMALL DESIGN the super-lightweight Ma 25 weighs in at only 980 g. Small enough to hold in the palm of your hand! tucked into its carrying case, the Ma 25 is one of our smallest, lightest portables. ACCURATE AND DEPENDABLE ENGINEERING Because it is portable, the Ma 25 has been engineered to be tough and reliable. take the Ma 25 everywhere with confidence. User-friendly knobs make adjusting frequency and hearing levels easy and comfortable! MA 25E EXTENDS FUNCTIONALITY OF MA 25 the Ma 25e extends the Ma 25 functionalities with an automatic test according to Hughson-Westlake. parameters can easily be adapted to your personal preferences. the talk forward function makes the Ma 25e easy to work with, particularly in sound booth installations. TECHNICAL SPECIFICATION Test Signals – Sinus and warble tone (pulsed and continuous) Test Frequencies Hz – 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Level Steps – 5 or 1 dB Hearing Level Range – 90 dBHL at 0.25 and 8 kHz, 70 dBHL at 0.125 kHz, -10 dBHL – 100 dBHL Audiometer Class – Class 4 according to En 60 645-1 Power Supply – 3 AA batteries (100 hours life time typically) or optional power supply Click Here To Download Catalogue
Maico MA25 Audiometer
-
MB 11 Classic offers fast, automated Auditory Brainstem Response hearing tests for newborns. An integrated automatic impedance check ensures good testing conditions. Features: Very fast automated ABR Screening with CE-Chirp® stimulus Simultaneous testing of both ears at the same time Advanced FSS algorithm provides “PASS” or “REFER” result Automatic impedance check ensuring precise and clear signal conditions Automatic data export for easy tracking Sanibel Infant EarCups™ and Snap Electrodes
Maico MB 11 Classic (Binaural Automated ABR Hearing Screening for Newborns)
-
The MB 11 Brainstem Evoked Response Audiometer (B.E.R.A) stands for innovation in Newborn Hearing Screening — the unique, patented Auditory Brainstem Response system offers a fast automated ABR hearing test for newborns without the use of adhesive disposables. To grant babies the comfort of disposable-free ABR screening, our BERAphone® comes with integrated electrodes and a speaker with ear cushion in a single unit. If the BERAphone® detects and verifies a response at 35 dB nHL, the test result is PASS. FEATURES AT A GLANCE Fast and automated ABR screening with reliable results in seconds Unique BERAphone® with integrated electrodes saves costs for disposables Automatic impedance check indicates test conditions CE-Chirp® Stimulus Stimulus level of 35 dB nHL ABR System with Patented CE-Chirp® for Fast Results Our MB 11 BERAphone® is equipped with a unique CE-Chirp® which stimulates all regions of the cochlea at the same time to generate much higher responses and faster results than a standard click. This leads to highly accurate results for Auditory Brainstem Response Tests under normal nursing conditions. Easy for You, Comfortable for the Baby The MB 11 BERAphone® makes ABR hearing tests for newborns easier for both sides: When the newborn is asleep or calm, apply the electrode gel at the three electrode sites on the baby’s head. Place a drop of electrode gel on the integrated electrodes. Position the MB 11 BERAphone®, surrounding the baby’s ear with the earphone and resting the electrodes on the prepared sites. No adhesive disposables are needed. You will save costs and the babies will not experience any pulling or pain while being tested. Baby-friendly and cost-efficient, that is the key for effective ABR testing. User-Friendly PC Software Keeping track of your test and patient data of ABR tests is easy with the MB 11 BERAphone®. Transfer your data to a PC via USB connection and make use of the intuitive PC software that comes with the MB 11 BERAphone®. The simple user interface enhances the ease of training and allows even first-time users to navigate easily through the software. The “Traffic Light” display for electrode contact and test quality provides easy to understand feedback to screeners. If you want to use HiTrack or Oz, there are export functions ready for you to use. The MB 11 BERAphone® makes Newborn Hearing Screening and ABR hearing tests easy! TECHNICAL SPECIFICATION MB 11 BERAphone® Dimensions / Weight – 120 mm x 93 mm x 30 mm / 142 g Display – Test result (Pass, Refer or Abort), test diagram with line towards PASS, signal quality or EEG, traffc light for impedance test Languages – English, German, Spanish, French, Italian, Dutch, Turkish, Hungarian, Russian, Chinese, Japanese PC interface – USB Power supply – USB-Port 5V DC max. 400 mA BERAphone® One Channel – 3 reusable stainless-steel electrodes Gain – 69.6 dB CMR Ratio – >110 dB at 80 Hz Transducer – Integrated dynamic speaker (8 Ω) Dimensions / Weight – 160 mm x 87 mm x 60 mm / 285g ABR Stimuli – CE-Chirp® Stimulus rate – ~90 /s Stimulus level – 35 dB nHL Test mode – monaural Impedance test – Automatic pre-test Test duration – 16 s to 180 s Artifact rejection level – 100 µV Computer Requirements Type – 2 GHz or more RAM – Minimum 1 GB Hard Disk – Minimum 10 GB free disk space Interface – USB 1.1, 2.0 or 3.0 Display – Min. resolution 1280 x 1024 or higher Graphic card – Direct X9 with WDDM 1.0 or higher Operating System – Windows7 Professional, Windows8 Pro, Windows10 Pro Click Here To Download Catalogue
Maico MB11 Brainstem Evoked Response Audiometer
-
The Mini 250 hearing test booth is ideal for series examinations, for example in schools, health authorities and occupational medicine. It takes up very little space and still offers very good noise insulation. Ready to start immediately: The Mini 250 is delivered completely assembled by MAICO. With the castors also preinstalled, it is easy to move – and can be used immediately! Features: Sound insulation up to 52 dB For audiometry with air and bone conduction, speech and all tests The sound-absorbing ventilation system ensures a good indoor climate Integrated socket strip and table for audiometer Security door with magnetic seal Large observation windows with laminated safety glass Specifications: Internal dimensions: L x W x H: 604 x 860 x 1680 mm External dimensions: L x W x H: 827 x 990 x 1963 mm Click Here To Download Catalogue
Maico Mini 250 (Compact and Soundproof)
-
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4″ touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE Combo device with small footprint Customizable to suit individual needs High resolution and quick screen transitions Full touch-based interface for intuitive handling Probe tone 226 Hz, 678 Hz, 800 Hz Optional high-frequency probe tone 1 kHz Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral) Reflex Decay test (ipsilateral and contralateral) ETF test for intact and perforated eardrums Air conduction audiometry Bone conduction audiometry Built-in printer or data transfer to PC Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management Comprehensive test protocols Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns Stay focused on your patients The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient’s top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result. Printing made easy Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration. Compatible to Sessions: Get ready for fast data transfer! Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements. TECHNICAL SPECIFICATION Tympanometry Probe Frequency – 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB Optional High Frequency – 1 kHz ± 1%, 69 dBSPL ± 1.5 dB Pressure Range – -600 to + 400 daPa Accuracy of Pressure – ± 5 % or ± 10 daPa Volume Range – 0.0 to 6.0 ml (compensated) Compliance Range – 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz Accuracy of Volume – ± 5 % or 0.1 ml Test Time Measurement – 3 – 5 seconds Acoustic Reflexes Test Frequencies – 0.5, 1, 2, 4 kHz ± 1 % Test Noise – BB, LP, HP Test Methods – Ipsilateral, contralateral Level Ipsilateral – 70 to 105 dBHL Level Contralateral – 70 to 120 dBHL Level Setting – Automatic, fxed Ipsilateral Reflex – Test With AGC Reflex Decay Standard – Probe frequency 226 Hz Test Frequencies – 0.5, 1, 2, 4 kHz ± 1 % Test Noise – BB, LP, HP Level Ipsilateral – 70 to 105 dBHL Level Contralateral – 70 to 120 dBHL Eustachian Tube Function Test Methods – Intact and perforated Pressure Range – -600 to + 400 daPa Audiometry Test Signals – Sinus and warble tone, (pulsed and continuous) Test Frequencies – 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded from bone conduction test frequencies) Level Steps – 5 or 1 dB Hearing Level Range AC – -10 to 120 dBHL Hearing Level Range BC – -10 to 80 dBHL Masking Noise – Narrow band and white noise Device General Display – 10.4″ Graphic LED-Display with resistive touchscreen PC Interface – USB Probe – Lightweight diagnostic Shoulder-Box with built-in control light and switch Printer – Fast 4 inch thermal printer Power Supply – Mains 100 to 240 V~ ± 10 %, 50 – 60 Hz ± 10 % Dimensions / Weight – W 30 x D 34.5 x H 14.8 cm / 3.2 kg Languages – English, German, Spanish, French, Polish, Turkish, Russian, Chinese Click Here To Download Catalogue
Maico TouchTymp MI36 Tympanometry
-
Strong structure in stainless steel/resin coated rectangular tubes. Adjustable head and leg sections. Artificial Leather Padding Complete with stainless steel bowl Ø30cm & leg holders Guard rails dimensions: 1860X600X700mm Backrest: 0 -75 Loading Capacity: 200kg
Manual Delivery / Examination HF-DB 100
-
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications: Eyepiece focusing range: ±5D The top point diopter measuring range: 0—±20D The minimum measuring square value: 0.125D The shuttle lens measuring range: 5A The shuttle lens square value: 1A The cylinder lens axial range: 0—180° The cylinder lens axial square value: 5° The maximum diameter of the measured lenses l00m/m Power supply: AC 110V-6V DC 3V Note: This item is AC 110V; The battery is not included!
Manual lensmeter