-
Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks with the volume of 500 ml within the temperature range from the ambient one to 450°С Advantages: – two-zone heating with the possibility of switching off the heating of the top zone – the heating mantle is equipped with electronic temperature controller – heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device – automatic break of the device in case of overheating (the operation returns to normal when the temperature reaches allowable limit) – metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion Technical specifications: – Housing material: steel covered with powder paint resistant to chemical action – Heating element: fabric fiberglass with nichrome wire – Maximum heater temperature, °С – 450 – Flask volume, ml – 500 – Weight, kg – 3.3 – Dimensions (LхWхH) – 220х325х120 – Power supply voltage (50/60Hz), V – 220-230 – Power consumption, W – 230
Heating Mantle PE-4100M (0.5L) analogue
-
Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks made of heat-resistant glass with the volume of 2000 ml within the temperature range from the ambient one to 400°С Advantages: – two-zone heating with the possibility of switching off the heating of the top zone – heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device – indication of parameters on the liquid crystal display – electronic (PID) temperature controller – automatic and heating tuning of the heating intensity – timer with visual and audible signaling of finishing of the heating – locking of the control to provide the protection against accidental change of the operation mode – possibility of connection of a remote sensor (option) – determination and indication of the possible faults and malfunctions – metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion Remarks: – the maximum heating temperature is reached when both heating zones are switched on – due to presence of heat losses, the liquid temperature in the vessel can never reach the maximum temperature of the heating element; therefore, the settable temperature is limited by a value of 400°С Technical specifications: – Housing material: steel covered with powder paint resistant to chemical action – Heating element: fabric fiberglass with nichrome wire – Maximum heater temperature, °С – 450 – Flask volume, ml – 2000 – Weight, kg – 3.8 – Power supply voltage (50/60Hz), V – 220-230 – Power consumption, W – 470
Heating Mantle PE-4130 (2.0L) Digital
-
Heating Mantle PE-4130M (2.0L) Analogue Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks with the volume of 2000 ml within the temperature range from the ambient one to 450°С Advantages: – two-zone heating with the possibility of switching off the heating of the top zone – the heating mantle is equipped with electronic temperature controller – heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device – automatic break of the device in case of overheating (the operation returns to normal when the temperature reaches allowable limit) – metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion Technical specifications: Housing material: steel covered with powder paint resistant to chemical action Heating element: fabric fiberglass with nichrome wire Maximum heater temperature, °С – 450 Flask volume, ml – 2000 Weight, kg – 3.8 Dimensions (LхWхH) – 220х345х130 Power supply voltage (50/60Hz), V – 220-230 Power consumption, W – 470
Heating Mantle PE-4130M (2.0L) Analogue
-
Load capacity: 28KGS 60cm (23.6”) diameter concaved aluminum base Tilt Adjustable chart holder for writing or sundries collecting 45cm (17.5”) height adjustment range to accommodate different height users Minimum Height: 80cm (31.5”) Maximum Height: 125cm (49.5”) Slide-in mounting plate can be used with various bottom-mounted medical device No need for tools to adjust the tilt of mounting plate for optimal view angle Cable Hook for cable management Utility baskets with cord hooks 7.3cm (3”) diameter dual-wheel medical casters for easy transition over uneven surface, anti-static, 2 with brakes, and 3 without brakes. ( Various medical casters are optional) Provide mobile mounting solution for various medical devices, including patient monitor, fetal monitor, defibrillator, infusion pump, etc.
Height Adjustable Rolling Stand with Concaved Base JRS-1001-10
-
The EuroVac® H-40 surgical suction pumps are electric, high-vacuum and high-flow suction pumps, designed as suction devices for operation rooms where a high-suction capability and a rapid response is required. Features: Compact design: high-resistance (impact and scratches) ABS, aluminium reinforced chassis. Four Ø80 mm: one anti-static and two with brakes. Long lasting, oil-free piston-type vacuum pump (until 90 L/min). Non-maintenance required. Precise high-vacuum gauge: 0-100 kPa (0-760 mmHg). High-visibility, Ø67 mm. Precise, steady suction pressure-regulating knob. Collection jar with overflow safety valve, in polysulfone or polycarbonate of 4 L (useful capacity 3.5 L). Possibility of using 1 or 2 suction jars. Collection jar support EN ISO 19054:2005. Available with supports compatible with the main disposable canisters. Hydrophobic bacteria filter, made in PTFE. With 99% particle retention and 99,99% bacterial challenge efficiency. With PVC or silicone suction tube. ON/OFF switch. Interruptor ON/OFF. 3 m electric cable housing. Selector knob of active collection jar with two positions for double collection jar pump (optional). ON/OFF foot-operated pedal (optional). Equipment dimensions: 960 x 430 x 340 mm. Weight: 22 Kg Technical Specifications: Maximum pump flow ±5% calculated at 230 V / 60 Hz 40 L/min Maximum vacuum 85 kPa – 850 mbar – 640 mmHg Noise level 45 ± 1.5 dB (AS)/ 1 m Power 180 W Intensity 0.9 A Voltage 200 – 240 VAC (50-60 Hz) Available 100 – 120 VAC Storage temperature -40 ºC a 70 ºC -40 ºF a 158 ºF Operating temperature 7 ºC a 40 ºC 44 ºF a 104 º Click Here To Download Catalogue
Hersill EuroVac H-40 Surgical Suction Pump
-
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility. TECHNICAL SPECIFICATION OPERATING DATA Weight – 105 kg Dimensions – 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface) Packaging Dimensions – 105 cm Wide x 75 cm Deep x 160 cm High Operating voltage supply – 110 to 240 V~, 47 to 63 Hz (12 to 6 A) Power input – 120 W typically (max. 1.2 kW with auxiliary outlets used) Battery autonomy – 90 min typically Auxiliary power outlets – 4, with automatic protection O2, N2O and Air supply – 2.7 to 6.9 bar (39.1 to 100 psi) Screen – TFT 18.5″ (47 cm) projected capacitive touchscreen Protection class – Class I, gas analyser type BF defibrillation proof Classification – Class II b Storage – One front drawer with self-brake system and two back cabinets with door Lighting – LED bar below the screen controlled from the touchscreen Auxiliary integrated systems – Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device Communication ports – 1 x RS-232, 2 x USB, 1 x LAN Ethernet Fresh Gases (02, N20 and Air, electronically controlled) Fresh gas flow – 0 and 0.1 to 18 L/min 02/N20/Air Accuracy – 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 % 02 concentration – 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02) 02 Safety fresh gas (backup) – 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02 02 flush (+02) – 40 L/min standard (adjustable 25 – 75 L/min upon requirement) Breathing System (CABS) Autoclavable – 134 °C Weight of breathing system – 9.8 kg C02 absorber volume – 1.5 L Leakage – < 150 mL/min (at 30 hPa) Pressure limiting valve APL – 0 to 70 hPa Pressure relief valve – 125 hPa Vacuum safety valve – 0.3 hPa resistance at 60L/min – 5.80 hPa resistance at 60L/min – 2.90 hPa resistance at 30L/min – 3.55 hPa resistance at 30L/min – 0.89 hPa Internal Compliance at 30 hPa – 15 mL VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes: Volume Controlled Ventilation (VCV) VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV) VC-SIMV with Pressure Support (VC-SIMV-PS) * Pressure controlled (PC) modes: Pressure Controlled Ventilation (PCV) PC Synchronized Intermittent Mandatory (PC-SIMV) PC-SIMV with Pressure Support (PC-SIMV-PS) * Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+) Adaptive Pressure with Volume Guaranteed (APVG) * APVG Synchronized Intermittent Mandatory (APVG-SIMV) * APVG -SIMV with Pressure Support (APVG-SIMV-PS) * Pressure Support Ventilation (PSV) * (other trade names: PS, ASB, SPS, IPS) Non-mechanical Operation / Ventilation Modes Manual ventilation through the CABS system (Auto/Manual software controlled) Spontaneous ventilation either through the bellows (auto mode) or through the bag (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, …) Application field: Neonates, Pediatrics & Adults Tidal volume – 5 to 1500 mL Inspiratory pressure – 0 to 68 hPa Ventilation frequency - 3 to 120/min Inspiratory time – 0.05 to 16.6s l:E ratio – 5:1 to 1:8 Inspiratory pause – 0 to 60% Inspiratory flow – max. 150 L/min PEEP – 0 to 30 hPa Flow trigger – 0.2 to 15 L/min Pressure support – 5 to 50 hPa Ramp time – 0.1 to 2 s Maximum pressure – 0 to 68 hPa MONITORING 5″ (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm. Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas* Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas). Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS). Configurable interface: bright/dark, multi-language. Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume. Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic Click Here To Download Catalogue
Hersill Genesis Anaesthetic Machine
-
The V7 g intermittent low vacuum portable suction units have been specifically developed for gastric drainage, wound drainage and therapies requiring low flow conditions. Features: ABS ergonomical case and ancorage system tested to 10 g. Long life medical grade membrane type suction pump. Oil-free and maintenance-free. Digital vacuum display of 0-20 kPa (0-150 mmHg). Precise and stable vacuum control knob. Intermittence programer control knob: it allows to select between continuous aspiration and three different programmed timings: 10 sec ON – 5 sec OFF / 20 sec ON –10 sec OFF / 40 sec ON – 20 sec OFF. Indicator lights: ON, flashing, vacuum level, vacuum indicator and battery status. Maximum noise level: + 1.5 dB. Dual power supply and power: 100 / 240 VAC y 12 VDC. 35 W (AC) y 30 W (DC). Long battery life. LED battery level lights. Flow rate: 5 L/min (Continuos/Intermittent). Maximum vacuum: 20 kPa -150 mmHg. Collection jar with overflow safety valve in polycarbonate or polysulfone of 1 L (useful capacity 0.75 L) PC1/PSU1 or 1.75 L (useful capacity 1.30 L) -PC2/PSU2. Also available with holders compatible with the main disposable canister. Hydrophobic bacteria filter, made of PTFE. With an efficiency of 99% in the retention of particles and bacteria of 99.99%. With PVC suction tube. ON/OFF swith with moisture protection. Equipment dimensions: 395 x 160 x 250 mm (with PC1 jar) and 428 x 160 x 250 (with PC2 jar PC2). Weight: 2,5 Kg. Technical Specifications: Power supply:100/240 Va<, 12Vdc, Battery Free air suction flow: 5 L/min Continuous/ Intermittent Maximum vacuum: 20 kPa, 150 mmHg Electric power: 35W (ac), 30W (dc) Internal battery: 12 V- 1,3 Ah, Ac-Pb 120 min Click Here To Download Catalogue
Hersill V7 G Intermittent Low Vacuum Portable Suction Machine
-
The V7 range of high vacuum portable suction units are ideal for use in healthcare facilities (surgery, gynaecology, ENT), homes, ambulances, transportation and use in emergency situations. Features: ABS ergonomical case and ancorage system tested to 10 g. Long life medical grade piston type suction pump. Oil-free and maintenance-free. Vacuum gauge of 0-100 kPa (0-760 mmHg). Precise and stable vacuum control knob. Indicator lights: ON, flashing, vacuum level, vacuum indicator and battery status. Maximum noise level: 49 + 1,5 dB (depending on model). Battery for long duration autonomy (consult models in which it is included). LED battery level lights. Collection jar with overflow safety valve in polycarbonate or polysulfone of 1 L (useful capacity 0.75 L) PC1/PSU1 or 1.75 L (useful capacity 1.30 L) -PC2/PSU2. Also available with holders compatible with the main disposable canister Hydrophobic bacteria filter, made of PTFE. With an efficiency of 99% in the retention of particles and bacteria of 99.99%. With PVC suction tube. ON/OFF swith with moisture protection. Equipment dimensions: 385 x 155 x 255 mm. Technical Specifications: Power supply Flow rate Maximum vacuum V7 ac 220 VaC 250 W 20 L/min 80 kPa 600 mmHg V7 dc 12 VDC 18 W 14 L/min 75 kPa 562 mmHg V7 plus ac 220 VAC 120 W 30 L/min 84 kPa 630 mmHg V7 plus dc 12 VDC 85 W 30 L/min 84 kPa 630 mmHg V7 plus b 12 VDC 85 W Battery 30 L/min 84 kPa 630 mmHg V7 plus b emergency 12 VDC 85 W Battery 30 L/min 84 kPa 630 mmHg V7 mx 110/240 Vac 12 VDC 160 W (AC) / 84 W (DC) Battery 30 L/min 84 kPa 630 mmHg Click Here To Download Catalogue
Hersill V7 Plus AC High Vacuum Portable Suction Machine
-
The V7 range of high vacuum portable suction units are ideal for use in healthcare facilities (surgery, gynaecology, ENT), homes, ambulances, transportation and use in emergency situations. Features: ABS ergonomical case and ancorage system tested to 10 g. Long life medical grade piston type suction pump. Oil-free and maintenance-free. Vacuum gauge of 0-100 kPa (0-760 mmHg). Precise and stable vacuum control knob. Indicator lights: ON, flashing, vacuum level, vacuum indicator and battery status. Maximum noise level: 49 + 1,5 dB (depending on model). Battery for long duration autonomy (consult models in which it is included). LED battery level lights. Collection jar with overflow safety valve in polycarbonate or polysulfone of 1 L (useful capacity 0.75 L) PC1/PSU1 or 1.75 L (useful capacity 1.30 L) -PC2/PSU2. Also available with holders compatible with the main disposable canister Hydrophobic bacteria filter, made of PTFE. With an efficiency of 99% in the retention of particles and bacteria of 99.99%. With PVC suction tube. ON/OFF swith with moisture protection. Equipment dimensions: 385 x 155 x 255 mm. Technical Specifications: Power supply Flow rate Maximum vacuum V7 ac 220 VaC 250 W 20 L/min 80 kPa 600 mmHg V7 dc 12 VDC 18 W 14 L/min 75 kPa 562 mmHg V7 plus ac 220 VAC 120 W 30 L/min 84 kPa 630 mmHg V7 plus dc 12 VDC 85 W 30 L/min 84 kPa 630 mmHg V7 plus b 12 VDC 85 W Battery 30 L/min 84 kPa 630 mmHg V7 plus b emergency 12 VDC 85 W Battery 30 L/min 84 kPa 630 mmHg V7 mx 110/240 Vac 12 VDC 160 W (AC) / 84 W (DC) Battery 30 L/min 84 kPa 630 mmHg Click Here To Download Catalogue
Hersill V7 Plus B Emergency High Vacuum Portable Suction Machine
-
Design of this head immobilizer make it compatible with all EMSS aluminum alloy stretchers and plastic spine boads
HM1-Head Immobilizer
-
Purpose: hot plate is intended for fast and uniform heating of beakers, flasks and other vessels. For example, vessels with sand (sand bath) Features: Ceramic coating of the heating platform endures long exposure of acids and alkalies under an elevated temperature. Technical specifications: – Housing material: steel covered with chemically resistant powder paint – Heating platform: duralumin covered with ceramic – Temperature control method – digital control – Maximum heating temperature, °С – 320 – Temperature setting discreteness, °С ±0.1 – Temperature non-uniformity throughout the platform °С – ±0.5°С – Hot plate dimensions, mm – 300х400 – Supply voltage (50/60 Hz),V – 220-230 – Power consumption, W – 1800 – Weight, kg – 11
Hot Plate ES-H3040
-
Technical specifications of Hot Plate: – Housing material: steel covered with chemically resistant powder paint – Heating platform: PTFE – Temperature control method – digital control – Maximum heating temperature, °С – 210 – Temperature setting discreteness, °С ±0.1 – Temperature non-uniformity throughout the platform °С – ±0.5°С – Hot plate dimensions, mm – 300×400 – Supply voltage (50/60 Hz),V – 220-230 – Power consumption, W – 2000 – Dimensions, cm – 41x31x14.5 – Weight, kg – 17
Hot Plate ES-HF3040
-
Purpose: hot plate is intended for fast and uniform heating of beakers, flasks and other vessels. For example, vessels with sand (sand bath) Advantages: • Aluminum platform provides high heating uniformity • High heating rate due to powerful heating element • Stepless power control Technical specifications: – Housing material: steel covered with chemically resistant powder paint – Heating platform: aluminum – Maximum heating temperature, °С – 350 – Hot plate dimensions, mm – 350×600 – Supply voltage (50 Hz),V – 220 – Power consumption, W – 2800 – Weight, kg – 11
Hot Plate ES-HS4060M
-
The HQ-760DY Dry Imager is a thermo-graphic film processor designed for digital radiography imaging. It is the one and only domestically engineered medical dry thermal imager. The HQ-DY series Dry Imager uses the latest direct dry thermal imaging technology which accommodates for a full range of applications, including CT, MR, DSA and US, as well as CR/DR applications for GenRad, Mammography, Orthopaedics, Dental Imaging and more. The HQ-Series Dry Imager dedicates to precision in diagnosis with its outstanding image quality, and offers affordable imaging catering to your needs. – Supports Mammography – Dry thermal technology – Daylight load film cartridges – Double tray, supports 4 film sizes – Speed printing, higher efficiency – Economical, stable, reliable – Compact design, easy installation – Straight forward operation, user-friendly Technical Specification: Print Technology Direct thermal (dry, daylight-load film) Spatial Resolution 508dpi (20pixels/mm) Grayscale Contrast Resolution 14 bits Film Tray Two supply trays, 200-sheet capacity total Film Sizes 8’’×10’’, 10’’×12’’, 11’’×14’’, 14’’×17’’ Applicable film Medical Dry Thermal Film (blue or clear base) Interface 10/100/1000 Base-T Ethernet (RJ-45) Network Protocol Standard DICOM 3.0 connection Image Quality Automatic calibration using built-in densitometer Control Panel Touch Screen, Online Display, Alert, Fault and Active Power Supply 100-240VAC 50/60Hz 600W Weight 50Kg Operating Temperature 5℃-35℃ Storage Humidity 30%-95% Storage Temperature -22℃-50℃ Click Here To Download Catalogue
HU.Q hq-760dy Dry Image X-Ray Film Printer (Mammo)
-
Application:Fractures of medium distal humerus Width: 12mm Thickness: 2mm
Humerus Distal Lateral Humeral Plate