-
Features Panoramic Imaging – By choosing a sensor, which improves the image quality while keeping radiation exposure to a minimum, Genoray has shown that it puts patient’s safety first. Cephalometric Imaging – When compared to the standard scanning method, PAPAYA PLUS has the shortest scan time out there  – Among patient discomfort, image’s swing, and distortion, they are reduced along with the short scan time. Tomography Imaging (Optional) PAPAYA PLUS added Tomography function and without hardware upgrade and considering of manufacturing of Tomography function; in addition to S/W, PAPAYA provides Tomography image. High Resolution Cephalometric Technology It is enough only 4 second for scanning cephalo image on fast mode.  This reduces motion artifacts. The Different Detector Types High-Definition images distinguish themselves from the old indirect conversion type of a CCD sensor. This should be the only way you view images User Friendly Face to face positioning / Fit each individual’s jaw shape. / Voice support system / Hand switch / Emergency switch / Wheelchair accessible Multi-Focus Function Multi-focus function ables to overcome operator’s mistake from patient’s faulty positioning and re-exposuring X-ray. By reconstructing image with software way, the panoramic images layer can be corrected by multi-focus function. Exposure Programs Lateral, AP, PA, Water’s view, Submento vertex, and carpus.  Click Here To Download Catalogue
Genoray Papaya Plus Panoramic Dental X-Ray
-
Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible. Exceptional Image Quality 9″ or 12” image intensifier 1K x 1K High resolution CCD Camera Wide FOV (Field-of-View) Low Dose, Low Noise High-Definition High Contrast Rotating Anode Tube X-Ray Dose Management Low Dose Mode Auto / Virtual Collimator Iris Collimator Compact & Intelligent Design Lightweight Architecture Intelligent operation Compact, Hybrid Body 7″ Touch Screen LCD Monitor 19-inch LCD Two Monitor Powerful Software Image Management DICOM 3.0 Database Management Approved Format Air Cooling High Performance Protection from Overheating and Damage Click Here To Download Catalogue
Genoray ZEN-7000 Surgical Mobile C-Arm
-
OXYGEN SET – GENTECOX-087Oxygen Flowmeter111,200.00GentecOX-090Oxygen Regulator111,800.00GentecOX-095Oxygenhumidifier13,800.00Gentec
Gentec OXYGEN SET
-
100% Cotton One-piece straight back Side hand access Regular 42” length & 44” Tall Length
Green Gown
-
FreeFill – the newest filling system for liquid Denut’s gutta-percha. Wireless – minimizing the time and materials needed to fill the channel. The use of the device ensures the highest quality and precision in filling the ducts. Wireless device 3-dimensional obturation system. Fantastic combination of filling with the method of vertical compaction. Provides excellent hermetic sealing of the root canal. Together, the entire main channel and side channels are filled. Excellent control of the honing part and filling of anatomically complex channels. Two mobile systems in one device (hot plugger and obturator). The obturator cover can be sterilized in an autoclave. The device is covered by the manufacturer’s one-year warranty (application tips and tips for the plugger are consumable – they are not covered by the warranty). Technical data – charging system and batteries: operating voltage – DC 3.7 V, input adapter – AC 100 – 240 V, 50/60 Hz, output – DC 7.5 V, 2.5 A, indicator indicating the status of charging / charging, time to full charge – about 1 hour, two power supplies included. Gun – Obturation Gun: heater – DC 3.7 V, 10 W, temperature range – 1500C, 1800C, 2000C, 2200C (visible on the display), working time with continuous use of the gun – about 120 minutes (when the battery is fully charged), automatic shutdown after 5 minutes of non-use (battery saving), automatic shut-off after 15 minutes of continuous operation (prevents burning of the heater), ECO system (energy-saving) – temperature maintained at 1200C in order to warm up to a given temperature faster, induction switch placed in the handle – switches the heating on / off depending on whether the device is held in hand or not, the possibility of setting the needle in any direction (once the bent needle can be used to fill the lower or upper one). Plugger – obturation pen: heater – DC 3.7 V, 10 W, temperature range – 1500C, 1800C, 2000C, 2200C (visible on the display), working time for continuous use of the plug – 60 minutes (when the battery is fully charged), 3600 power button, 6 directions of injection tips setting, automatic shutdown after 5 minutes, information about proper connection of the needle, information about the damaged needle. Set contains: gun – obturation gun – 1 piece, gun stand with built-in charger – stand for gun – 1 piece, plugger – obturation pen – 1 piece, stand for plugger with built-in charger – stand for pen – 1 piece, injection needles – gun needle – 3 pieces, pen tip – pen tip – 4 pieces, the key for injection needles – adapter – 1 piece, pusher for hot gutta-percha – 2 pieces, thermal casings – heat insulator – 2 pieces, cleaning brush – brush – 1 piece, power supply – 2 pieces, gutta-percha – 20 pieces, instruction – 1 piece. There is a possibility to buy tips for the plugger: set – 4 sizes after the play, size F – white (thin), FM size – yellow, size M – red, ML size – black.
Gutta Percha Obturation System
-
Model HBD-116 HBD-286 Vaccine storage capacity 92L 90L Gross volume 121L 198L Gross weight (kg) 58 82 Ambient temperature <43°C <43°C Compressor Danfoss compressor Danfoss compressor Refrigerant R134a R134a Exterior Dimensions( mm) (H×W×L) 832×755×630 832×755×630 Packing Dimensions (mm) (H×W×L) 950×837×760 950×837×760 Container load( sets) 20’/40’/40H 42/84/126 24/54/81 Power Consumption: stable running 0.38KWh/24h 4.36KWh/24h
Haier -25°C Vaccine & Icepack Freezer
-
Model HBD-70 HBD-200 HBD-380 Vaccine storage capacitLJ 45L 90L 200L Gross volume 71L 198L 340L Gross Weight(kg) 70 115 165 Ambient temperature 10 C-43 C 10 C-43 C 10 C-43 C Refrigerant R134a R134a R134a Edžterior Dimension ( mm) (W×D×H) 610×306×360 610×997×366 1644×650×846 Packing Dimension (mm) (W×D×H 880×756×760 880×1325×760 1764×770×1046 Container load (sets)ϮϬ’/ϰϬ’/ϰϬH 42/90/135 24/54/81 18/36/36 Holdoǀer Ɵme t ϰϯΣC >27H >31H >37H Power consumpƟon:able running 0.64 KWh/24h 1.32 KWh/24h 2.86 KWh/24h Power consumption: ool down test 2.4 KWh/24h 4.01 KWh/24h 4.32 KWh/24h
Haier 2°C~8°C Ice-Lined Refrigerator
-
HBC 60 Solar driven vaccine refrigerator: HBC-60 is driven by the sun, directly from solar panels. This appliance does not need battery storage or fuel for power. It is designed for the region with enough sunshine and poor electricity. Driven by solar panels without any battery, this refrigerator will not bring any negative impact to the environment. Features: Driven by solar power, environment friendly No battery for storage of power No need for power and fuel, low cost Digital display of temperature Easy installation Easy maintenance, only the solar panels need to be maintained Stainless steel interior liner Lock design, keep safety of vaccines
Haier 2°C~8°C Solar Vaccine Freezer
-
Refrigerator & Freezer Combination, Separately Control Excellent Performance Refrigerator 2~8C, freezer -20~-40C Reasonable Structure Large refrigerator; stainless steel, arch out door for convenient clean Key Function USB port, can record the temperature in one month automatially Separate display of refrigerator and freezer, easy observation Remote alarm and monitor in internet (optional) Divisible drawers and shelves for different items storing Multi-malfunction alarms, ece cautionary alarm
Haier 2°C8°C/-2°C-4°C Pharmaceutical Refrigerator with Freezer
-
Haier Biomedical Biological Safety Cabinet HR30-IIA2 has a world famous HEPA/ULPA filter which means the air filtering is cleaner. This safety cabinet has an independent high-efficiency motor to supply air, compensate filter membrane etc. automatic pressure compensation and has a flow rate of <10%. The HR30-IIA2 has a uniform downdraft, high-speed inflow, sample and user in the safe environment. Benefits ULPA filtration system Intelligent alarm Airflow blocking patent Electrical leakage protection Specifications HR30-IIA2 Working voltage and frequency 220V±10%,50±1 Hz Power (VA) 1300 Power of blower (W) 350 Airflow circulation 220/50 Main filter typical efficiency ULPA,99.9995%@0.12Œºm Exhaust filter typical efficiency ULPA,99.9995%@0.12Œºm Downflow velocity (m/s) 0.3
Haier HR30-IIA2
-
Product Specification Class Class II Product Type Type A2 Model HR40 Operator 1 Interior Dimensions 1200*610 *680 mm Overall dimensions 1360*780 *2200 mm UV light Greater Than 30w Noise Less than 62dB(A) IIIumination Greater Than 800Lx Inflow Air Velocity Greater Than 0.6m/s Downflow Air Velocity Greater Than 0.3+- 0.02m/s Cleanliness CLASS 100@ Greater Than 0.5um Product Other Details: Product Feature: Fission structure : The front panels are detachable and easier to remove for filter and filter. Visible windows: with antiultraviolet toughened glass and the height of glass can be adjustable. If the height is higher than safe level, the audible and visual alarm will be opened. The cabinet: all manufactured by 304??? stainless steel material and the left, right and back bins of cabinet are manufactured together with arc angle will make easier to clean the side of cabinet. Cabinet feature: Contaminated Pressure Plenum: Negative Unitized drain pan beneath the work surface allows best arm position the user’s lap. The airflow design creates a more impenetrable air barrier or momentum air curtain at the front of the cabinet, increasing the cabinet’s protective capabilities and avoiding cross infection. This kind of design standard is comply with NSF4911 standard. With strong wind form the draught intake in side of cabinet, which will clear the round airflow up in lateral cabinet and prohibit the moving of contamination. Ultra-high efficiency filter system: input and output of air will be filtrated by ULPA filter and its efficiency is more than 99.999%. the pressure sensor will watch the working condition of filter from time to time and alarm the operator if the operator if the pressure is over the setting value. Ultraviolet light safety: the UV light cannot be opened when the fan, visible window and fluorescent light are running. Interlock function for two fans ( blower and exhaust fan ): When the exhaust fan stops, the blower will stop automatically and alarm device will begin to work. When the blower stops, the exhaust fan will continue to work and the alarm system will indicate the fault of blower. Displaying data in the screen: Air-exhaust value ( m3/h ) the velocity of air laminar flow ( m/s ) counter for exhaust fan counter for blower. Safety control system: Alarm for low air exhaust value Alarm for low air-velocity of down laminar flow Alarm for fault of exhaust fan Alarm for closing condition of visible window When the visible windows is opened, the UV light will be closed automatically. When the fluorescent light is on working, the UV light will be closed automatically. When the blower begin to work and then the UV light will be off after air laminar flow is created. The blower will be off automatically if the exhaust fan happens some trouble. The exhaust fan will increase his rotate speed automatically in order to keep the working space in negative pressure inside cabinet in case something wrong happens with the blower. Microprocessor will counteract the gradually increased resistance in filter. It will keep air inflow and downflow in normal condition under any conditions
Haier HR40-IIA2
-
Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye’s refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing. Features of Handheld Digital Auto-refractometer: Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that’s it. The result will be automatically shown in 5 seconds. Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors. Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia Technical Specifications of Handheld Digital Auto-refractometer: Item Range Interval Tolerance Spherical (S) Myopia Mode -9.00D~ +2.50D 0.25D ±0.50D or ±20% (whichever is greater) Normal Mode -6.00D  ~ +8.00D Cylindrical(C) -3.00D~0.00D 0.25D ±0.50D or ±20% (whichever is greater) Axis(A) 0°~180° 1° ±5°
Handheld Digital Auto-refractometer
-
Heating Mantle PE-4100 (0.5L) Digital Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks made of heat-resistant glass with the volume of 500 ml within the temperature range from the ambient one to 400°С Advantages: – two-zone heating with the possibility of switching off the heating of the top zone – heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device – indication of parameters on the liquid crystal display – electronic (PID) temperature controller – automatic and heating tuning of the heating intensity – timer with visual and audible signalling of finishing of the heating – locking of the control to provide the protection against accidental change of the operation mode – possibility of connection of a remote sensor (option) – determination and indication of the possible faults and malfunctions – metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion Remarks: – the maximum heating temperature is reached when both heating zones are switched on – due to presence of heat losses, the liquid temperature in the vessel can never reach the maximum temperature of the heating element; therefore, the settable temperature is limited by a value of 400°С. Technical specifications: – Housing material: steel covered with powder paint resistant to chemical action – Heating element: fabric fiberglass with nichrome wire – Maximum heater temperature, °С – 450 – Flask volume, ml – 500 – Weight, kg – 3.4 – Power supply voltage (50/60Hz), V – 220-230 – Power consumption, W – 230
Heating Mantle PE-4100 (0.5L) Digital
-
Purpose: the heating mantle is intended for heating liquids in 3 round-bottomed flasks with the volume of 500 ml within the temperature range from the ambient one to 450°С Advantages: – independent control of each heating element – two-zone heating with the possibility of switching off the heating of the top zone – heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device – indication of parameters on the liquid crystal display – electronic (PID) temperature controller – automatic and heating tuning of the heating intensity – timer with visual and audible signaling of finishing of the heating – locking of the control to provide the protection against accidental change of the operation mode – possibility of connection of a remote sensor (option) – determination and indication of the possible faults and malfunctions – metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion – complete set of supports is included Remarks: – the maximum heating temperature is reached when both heating zones are switched on – due to presence of heat losses, the liquid temperature in the vessel can never reach the maximum temperature of the heating element; therefore, the settable temperature is limited by a value of 400°С Technical specifications: – Housing material: steel covered with powder paint resistant to chemical action – Heating element: fabric fiberglass with nichrome wire – Maximum heater temperature, °С – 450 – Flask volume, ml – 3×500 – Weight, kg – 8.4 – Dimensions (LхWхH) – 610х310х120 – Power supply voltage (50/60Hz), V – 220-230 – Power consumption, W – 3×230
Heating Mantle PE-4100-3 (3Ă—0.5L) Digital with Set of Racks