-
Is a benchtop system which has complete integration in the hematology laboratories by the direct determination of ESR from blood/EDTA samples with its smart and innovative technology combining “ccd cam” and internationally accepted Westergren method. 40 sample loading positions, suitablity to continious loading for 23 minutes when you start running the instrument, being maintanence free, being environment-friendly, LCD touch screen and data transmission to LIS are just some of the advanced features of the analyzer which provides laboratory confort and productivity. Features: • Use of the same CBC tubes. No dedicated citrate tube needed • Westergren method by CCD camera • Use of smart cards • No reagents required, environmently friendly • 40 sample loading positions, up to120 tests/ hour • Continuous loading of samples untill the first result • First result available after 24 minutes and each following result within 5 sec. • 10 inch LCD touch screen • User friendly software • Built-in thermal Printer (optional external printer) • LIS connection • Optional Barcode reader Technical Specification: Principles: Westergren method by CCD Camera Sample Loading Positions: 40, Direct loading of Blood/EDTA Samples Throughput: Up to120 samples/hour Time to First Result: First result in 24 minutes Time to Result: 5 seconds Minimum Sample Volume: 2 ml Sample Test Volume: 2 ml-3 ml Barcode Reader: External (optional) Internal Printer: Yes LIS Communication: Yes Display: Liquid Touch Screen, 800×600 pixel Operating Environment: Temperature:15°C-35°C, Humidity: <80% Power Requirement: A.C. 110-230V <=300 VA  50/60Hz Dimension: 690mm(L) x425mm(W) x 315mm(H) Weight: 28 KG  Click Here To Download Catalogue
Biota SABIO140 Automated ESR Analyzer
-
The Bipap System makes a good performance in sleep center, home and other departments. From high to low acuity, simple to complex cases, adult to geriatric patients, Perlong Medical Bipap System offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring. Trust Points: Simplicity: easy to use, easy to take with your package anywhere. Choice: adapt the equipment to your patients and procedures freely. Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 4 modes: CPAP; S; T; S/T. Designed and manufactured by Perlong Medical with over 23 years experience in this area. Flexible configurations to suit your needs. International standard and advanced technology suitable for wide range use. Compact interface and screen display give you better operating experience. Over 2,000 units installed in the world. Features: TFT LCD screen displays the Ventilation parameters and alarming information. Integration breathing circuit design, ensure easy operating and keep tidy. Multiple working modes such as volume control and pressure limit, adapt to wide range patient. Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects; Optimized design and fine manufacture, cooperating sound absorption composite, unique super mute design. Unique shuttle knob design, easy to operate and use in house. No need to add water by stopping the machine, very easy to use. Safety: Three level alarming system, visual and sound alarm information. With lots of alarming, reminding and protection functions. Advanced power management control technology. Specifications            Ventilation modes: CPAP,S,T,S/T Frequency Adjusting range:3bpm-40bpm Increment:1bpm Inspiration time Adjusting range:0-3s Increment:0.1s IPAP Adjusting range:4cmH2O-25cmH2O Increment:0.5cmH2O EPAP Adjusting range:4cmH2O-20cmH2O Increment:0.5cmH2O CPAP Adjusting range:4cmH2O-20cmH2O Increment:0.5cmH2O Ramp time Adjusting range:0-60min Increment:1min Rise time Adjusting range:0.1s-0.5s Increment:0.1s Inspiration trigger Adjusting range: auto adjusting, 1-3 Increment:1 Expiration trigger Adjusting range: auto adjusting, 1-3 Increment:1 Flex Adjusting range:OFF, 1-3 Increment:1 Humidifier Adjusting range:0-5 Increment:1 Ppeak 0-30cmH2O Graphical display: Airway pressure histogram
Bipap Duo-level Non-invasive Ventilator
-
Bistos BT – 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3″ color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Features: 3″ color touch screen Standard Confirgurations: SpO2 and Pulse Optioal NIBP and Masimo SpO2 Short/long trend graphic/trend table display Audio and visual alarm, adjustable alarm limit Automatic brightness adjustment Accurate SpO2 reading during motion or low perfusion Perfusion index data / bar graphic display Pitch tone variation for pulse rate Internal memory for data storage SD card for easy software upgrade Over 8 hours of operation with the re-chargeable li-ion battery PC software for data review and analysis on a computer  Technical Specifications: Model BT-720 Display 4.3″ Color LCD Touch Screen SpO2 Measurement Range 0-100% Accuracy (70-100%) Adult/Pediatric +/- 2% Neonate +/- 3% Accuracy (0-69%) Unspecified Perfusion Index 0.05-20% Pulse Rate Range (bpm) 25-250 NIBP* (Optional) Method Automatic Oscillometric Operation Mode Manual/Automatic/STAT Parameter Systolic/Diastolic/Mean Systolic Range (mmHg) Adult 40-270 Pediatric 40-200 Neonate 40-130 Diastolic Range Adult 100-210 Pediatric 100-160 Neonate 10-90 Mean Range Adult 20-230 Pediatric 20-175 Neonate 20-100 SpO2 Masimo* (Optional) Masimo SpO2 Battery Type (Capacity) Li-ion (4400mAh) Run time 8 Hours Charging Time 8 Hours Interface RJ45, SD Card Slot Warranty 2 Years  Click Here To Download Catalogue
Bistos BT- 720 Patient Monitor
-
Bistos BT – 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4″ TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Features: 8.4″ TFT Color Screen – (Optional Touch Screen Upgrade) Standard parameters are ECG, Resp., SpO2, NIBP, Temp. Ultra-low power consumption Quiet operation High accuracy SpO2 reading Data transfer or firmware upgrade via USB 2 Years Manufacturer’s Warranty  Technical Specifications: Model BT-740 Display 8.4″ Color TFT Screen ECG Lead type 3/5 Lead Gain Selection x0.25, x0.5, x1, x2, x4, auto Sweep speed (mm/s) 12.5, 25, 50 Bandwith:(Diagnostic Mode) 0.05-130Hz Monitoring Mode 0.5-40Hz Surgery Mode 1-25Hz Strong Mode 5-20Hz Heart Rate Range (bpm) Adult:15-300 Pediatric/neonate: 15-350 Respiration Method Trance-thoracic Impedance Measurement Range 0-120rpm Sweep Speed (mm/s) 6.25, 12.5, 25 SpO2 Measurement Range 0-100% Accuracy (70-100%) Adult/Pediatric +/-2% Neonate +/-3% Accuracy (0-69%) Unspecified Perfusion Index 0.05-20% Pulse Rate Range (bpm) 25-250bpm NIBP** Method Automatic (Oscillometric) Operation Mode Manual/Auto/STAT Parameter Systolic, Diastolic, Mean Systolic Range (mmHg) Adult 40-270 Pediatric 40-200 Neonate 40-130 Diastolic Range (mmHg) Adult 10-210 Pediatric 10-160 Neonate 10-90 Mean Range (mmHg) Adult 20-230 Pediatric 20-175 Neonate 20-100 Temperature Range 0-50°C Parameter T1, T2 and TD IBP” Channel 2 Channel, 4 Channel Range (mmHg) -50-400 Printer* Type Thermal dot array Print Speed (mm/s) 12.5, 25, 50 Paper Size (mm) 50 CO2* Sidestream Masimo ISA / Bistos Mainstream Masimo IRMA / Bistos Multi-gas O2* Masimo ISA SpO2 Masimo* Masimo SpO2 CO* Method Thermodilution Range 0.2-20 L/min Battery Type (Capacity) Li-ion (440mAh) Run Time 6 hour Charging Time 4 hour Interface RJ45, USB, Nursing Call Warranty 2 Years  Click Here To Download Catalogue
Bistos BT- 740 Patient Monitor
-
Product Details: Minimum Order Quantity 1 Piece Model BT-350 Dimension 80mm (H) X 330mm (L) X 280mm (D) Application Hospital Brand Bistos Screen rotating 180 Degree LCD display 7″ wide TFT color LCD display  Product : Up to 150 patients date saving Fetal heart sound play and record in PC Multiple language support Quick guide display Various installation method Dual Pulsed Doppler: Ultrasound Frequency: 0.985MHz Intensity: 10mW/cm2 or less FHR Range: 30~240bpm FHR Accuracy: ±2% of Range Auto-detection of Dual Fetal Movement External Type Frequency Response: DC~0.5HZ Reference(Zero) Control Measurement Range: 0~99 units Printer: Thermal Array Type Print Speed: 1,2,3, cm/min, high speed Auto print: Off,10,20,30,40,50,60 min Paper Feeding Function Display: 3 Channels (FHR I, FHR II, UC) 7″ Wide TFT-Color LCD:800(W) X 480(H) BT-350LCD Large 7-segment volume lever LED : BT-350 LED Function: Mark Function FHR II Offset Function Auto Print function Fetal movement print function Multi-language quick guide function: BT-350 LCD Trend: Data Saving for 450 hours(3hr/person): BT-350 LCD Accessory Standard: Ultrasound Doppler Probe 2ea Event Marker Jack 1ea Power Adaptor Cord 1ea Probe Belt 3ea  Click Here To Download Catalogue
Bistos BT-350 Fetal Monitor
-
Central Monitoring System can be defined as a continuous observation or monitoring of a patient vital sign during treatment while on life support equipment for the purpose of guiding management decisions, including when to make therapeutic interventions and assessment of those interventions. Central monitoring system involves the connectivity of patient monitors together on a network which enables healthcare givers to monitor patients recovery progress from another remote location over a local or wide area network. Bistos Patient Central Monitoring System Software the monitor assistant has some functions below: Up to 10 and above bedside monitors connectable display of holographic waveforms of the view bed of single bedside monitor; display of ECG.RESP.CO2.PLETH IBP waveforms and so on. Alarm manage parameter alarm events for each bedside monitor; S-T segment alarm events; arrhythmia alarm events. Alarm prompt modes: sound and lightwave. Storage and review of 24-hour holographic waveforms Storage and review of up to 240-hour trend data for each bedside monitor Storage and review of u to 720-item alarm events for each bedside monitor Review of five parameters and 6minutes short trend for each bedside monitor All the review information will be stored under off-state Display of continuous multi-lead ECG and single-lead arrhythmia analysis for each bedside monitor. Trend records and alarm records can be output according to a certain format. Patient information management: receive cancel input and educe Central Monitoring System gather function: relying on the data transmission the system has the capability that in different position could simultaneously monitor the bedside monitors in the courtyard All-round system help information including operation guide of this system and bedside monitor. Multi-language display interface support screen (dual-screen display) Support keyboard and mouse input Bistos Patient Central Monitoring Specification: System Configuration Demand 1. Computer configurationCPU: 1GHz or aboveMemory: 4G or aboveHard disc: 500GB or aboveNIC: 100M self-adaptiveSound card: 16-bitMonitor: 19 inch or above Operating system: WINDOWS 7 or above 2. Printing system: printer 3. Switch/ Hub: 10M/100M self-adaptive 4. Network cable: Straight-through cables (same colour definition for the 2 ends)
Bistos Central Monitoring System
-
Unit Brand Blood Bags Single 450 cc – Polymed Blood Bags Single 250 cc – Polymed
Blood Bags
-
It is suitable for blood collections in donation room as well as outdoor camps. It ensure smooth & gentle mixing process, volume accuracy, precise monitoring of time & flow rate. Features: Unique modern sensor and LED display. Preset volume of blood collection function. Soft shaking mode, improves the survival of effective components in the blood. Shaking auto stops. Technical Features : Measuring Range 0~1200ml Measuring Accuracy 2% Display Accuracy 1ml Liquid Proportion 1.05g/ml Collection Speed 0.5~3ml/s Swing Frequency 30~32 r/min Swing Angle 13±2° Alarm Audio and visual alarm Power Consumption 12W Power Supply AC110/220V±10%, 50/60Hz External Size(W*D*H) mm 218*172*160 Packing Size(W*D*H) mm 310*260*210 Net Weight(kg) 2.8 Gross Weight(kg) 4.1
Blood Collection Monitor
-
CODE DN-BGA10-A Blood Grouping A 10ml DN-BGA10-B Blood Grouping B 10ml DN-BGA10-AB Blood Grouping A/B 10m DN-BGA10-SERA Blood Grouping D 10ml DN-BA10 Bovine Albumin 30% DN-AG10 Anti-Human Globulin 10ml DN-BGA10-A Blood Grouping A 10ml DN-BGA10-B Blood Grouping B 10ml DN-BGA10-AB Blood Grouping A/B 10ml DN-BGA10-SERA Blood Grouping D 10ml DN-BA10 Bovine Albumin 30% DN-AG10 Anti-Human Globulin 10ml
Blood Grouping
-
The two-piece T-handle design is procedurally efficient, simple to use, and fits comfortable in the hand The T-handle bone marrow biopsy needle features a trocar-tapered stylet point and a triple-crown cannula tip Manufacturer NO TJC6011 Brand Jamshidi Manufacturer CareFusion Application Bone Marrow Biopsy / Aspiration Needle Gauge 11 Gauge Handle Material Plastic Introducer Without Introducer Length 6 Inch Needle Material Stainless Steel Sample Bone Marrow Sterility Sterile Style T-Handle Tip Type Trocar Tapered Stylet Point / Triple Crown Cannula Tip UNSPSC Code 42142504
Bone Marrow Aspiration Needle
-
Cortical Screw (Half & Full threaded) – 2.7mm,3.5mm,4.5mm, Cancellous Screw (Half & Full threaded) – 3.5mm,4.0mm,4.5mm,6.5mm, Cannulated Cancellous Screw – 3.5mm,4.5mm,7.3mm, Countersink Cannulated Cancellous Screw Self-tapping locking Screw – 3.5mm,5.0mm, ScrewHoleInsert – 3.5mm,5.0mm,
Bone Screws