-
KT88-3200 Digital Brain Electric Activity Mapping collects EEG signal with electrodes, via integrated amplification, A/D transformation, PC auto-analysis, FFT, to form electroencephalogram that displays with color depth. The product is applicable for checking such diseases as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors. Features: Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling. Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system. Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform. Digital filter system can be set as required, providing different window types EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters. Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment. Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback. Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on. Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted. Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling. Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research. Integrative image and character report, report can be edited in mode and switched to Word document. Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis. System parameters and display modes can be set as required, which meets different user’s requirement. Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks. Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image. SpO2 function is optional. Technical Specifications: 32 channels of EEG Sampling rate: 200 dots/s Accuracy: 12bit Input impedance: ≥10MΩ Patient leak current: < 10µA Noise level: ≤5µVp-p CMRR: ≥90dB Magnification multiple: 10000 Filter constant: all digital and free enactment Display speed(paper speed): 5, 10, 15, 30, 60, 120 mm/s Amplitude: 1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50µV Playback speed:1 time, 2 times, 3 times, 10 times, 20 times, 40 times, 60 times 50Hz interference suppression: ≥30dB Safety type:Class II, type BF applied part Accesories: EEG lead EEG electrode Data line Headgear Strobe light Strobe light power supply PC software CD User Manual Earth wire EEG bracket Aluminum block Click Here To Download Catalogue
Contec KT88-3200 Electroencephalogram (EEG) Machine
-
The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Features: Polaris.com, a powerful data management system, supports the straightforward administration and organization of diagnostic data. Modern communication interfaces (HL7 and GDT/BDT) enable integration into hospital and practice information systems. Digital Video Software allows synchronized digital video for EEG systems using webcam, professional HD camera, or picture-in-picture as per requirements. EEG Mapping, offers amplitude with spectral and frequency online mapping during acquisition, even with single channels and montages. Spike and Seizure Detection Software with a high sensitivity and a stunningly low false positive rate. Polysmith* combines sleep analysis software with recording devices to provide quick and precise data analysis – for a complete PSG solution customized to individual needs. EEG Trend Program converts EEG signals into clear trend graphs making them easy to interpret (aEEG, DSA, CSA, Power FFT). Smart vital signs interface for holistic multimodality assessment of patient, with capability to pull up 8 channels from bedside monitors Live View Panel offers intuitive real-time management of diverse neuromonitoring data from a centralized location. Amplifier: high-quality amplifier with 38 to 256 channels realizes wide-band EEG recording from slow shift to fast ripple. Brain function mapping system: a comprehensive and sophisticated system for brain function mapping reduces timeconsuming procedures by combining cortical stimulation, easy switch between stimulation and recording, and a brain function mapping report all in one place. EEG scope: data reviewer that allows review of previous EEG while monitoring, acquiring, and opening up to 4 EEGs at the same time. 3D voltage mapping: whole head maps offer a complete overview and better interpretation of the topography of EEG abnormalities. Customizable Main Menu that allows registration of examination protocol buttons on the main menu. Each button has user-defined settings for an examination which can be adjusted for different examination conditions and methods Note Window offers to save up to 1,000 sections of waveforms for comparison by dragging and dropping. Up to 100 copied waveforms can be registered as sample data for comparison with other patients or teaching purposes. NeuroReport, which is integrated in all Nihon Kohden EEG systems, offers individually configured report templates, including adaptive auto text functions, for fast and simple reporting. It guarantees maximum flexibility and compatibility. Technical Specifications: Routine EEG composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK Electrode junction box: JE-921A Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart: KE-122A Stand: KC-001A LCD display: Local purchase EMU Composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK 256 channel electrode junction box: JE-120A-256 Input box converter: QI-123A Mini flat junction box: JE-125AK Mini flat junction box: JE-226AK Mini flat junction box: JE-227AK Mini flat junction box: JE-228AK Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart with printer table: KD-029A Stand: KC-001A LCD display: Local purchase Extension unit: MS-120BK Switch box: PE-210AK Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation  Click Here To Download Catalogue
Nihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine