Ergometer CRG 200 is dedicated for Exercise Stress Tests System CardioTEST. The Ergometer has been designed according to modern technologies. It is controlled from PC equipped in CardioTEST software. Load level is controlled by a microprocessor, therefore it does not depend on speed, which in turn can be adjusted according to patient’s individual needs. Ergometer is equipped with ECG mode recording 12 standard leads.
Technical Specifications:
Cooperation with the CardioTEST cardiovascular exercise system and AsTER cardiac rehabilitation system,
Control using a computer through the RS-232 port,
Braking: a processor-controlled brake with torque measurement,
Load range: 25 – 1000 W,
Speed ​​range: 20 – 150 rpm,
Load independent of the number of turns,
Built-in ECG module,
12 standard leads in diagnostic mode,
2 leads in training mode,
Sensitivity 2,5 / 5/10/20 mm / mV,
Shift 25/50/100 mm / s,
Digital filters 25 Hz, 35 Hz, 50 Hz, anti-frit filter,
Digital filter of the isoelectric line,
Measuring range HR 15-240 bpm,
Maximum patient weight 200 kg,
Power supply: 230 V, 50 Hz, 60VA,
Dimensions: (LxWxH) 1190x600x1370 mm.
CardioTEST Software:
excellent quality of ECG waveforms thanks to the use of digital filters eliminating the swimming of the isoelectric line and disruption of muscle origin,
uninterrupted recording and presentation of 12-lead ECG signal,
presentation of averaged P-QRS-T units with 12 leads along with the results of ST level and slope measurements,
automatic HR measurement, ST level and ST segment slope,
automatic control of cycloergometer and treadmill load,
archiving and printing of the research report,
automatic determination of measuring points with the possibility of manual correction,
automatic arrhythmia analysis,
presentation of parameters regarding: test phase, current load, stage time and total effort time,
monitored parameters: rhythm rate, MET, double product, blood pressure, level, ST segment slope and load,
real-time ECG printout,
preview of trends of all measured parameters during the test,
alarm system for monitored parameters and arrhythmia,
an option to automatically measure blood pressure,
archiving and printing a report enabling a reliable assessment of the study (such an report contains ECG, average P-QRS-T assemblies and a table with measurement results),
standard test protocols and the ability to define your own protocols also in RAMP mode,
preview the report on the screen before printing the report,
function of reanalysis of the performed test,
presentation of 3D trends illustrating ST segment changes.